![Allot NetEnforcer AC-1000 Series Скачать руководство пользователя страница 67](http://html1.mh-extra.com/html/allot/netenforcer-ac-1000-series/netenforcer-ac-1000-series_hardware-manual_2903763067.webp)
Chapter 4: Redundancy
NetEnforcer AC-1000 Hardware Guide
4-3
Configuring the AC-1010 via NetXplorer
1.
Log into NetXplorer
2.
Right click the NetEnforcer you wish to configure in the Navigation
Pane
3.
Select
Configuration
from the drop down menu.
4.
Open the
NIC
tab and in the
Action on Failure
field, set INTERNAL1
and EXTERNAL1 to
fail paired port
.
Figure
4-1 – NIC Tab AC-1010 – NetXplorer Configuration
5.
Open the
Networking
tab and set the
Redundancy Mode
as required to
Parallel
or
Serial
.
6.
Select the
Enable Bypass Unit
checkbox.