Configuration of the camera
STINGRAY Technical Manual
V4.4.2
300
0xF1000800
0xF1000804
IO_OUTP_PWM1
Stingray housing and board level cameras:
See
Table 31: PWM configuration registers
0xF1000808
0xF100080C
IO_OUTP_PWM2
0xF1000810
0xF1000814
IO_OUTP_PWM3
0xF1000818
0xF100081C
IO_OUTP_PWM4
0xF1000840
IO_INP_DEBOUNCE_1
Table 65: Advanced register: Debounce time
0xF1000850
IO_INP_DEBOUNCE_2
0xF1000860
IO_INP_DEBOUNCE_3
0xF1000870
IO_INP_DEBOUNCE_4
0xF1000FFC
GPDATA_INFO
See
Table 170: Advanced register: GPData buffer
0xF1001000
...
0xF100nnnn
GPDATA_BUFFER
0xF1100000
PARRAMLIST_INFO
See
Table 156: Advanced register: Parameter-
0xF1101000
PARAMLIST_BUFFER
Note
Advanced features should always be activated before
accessing them.
Note
•
Currently all registers can be written without being
activated. This makes it easier to operate the camera
using
Directcontrol
.
•
AVT reserves the right to require activation in future
versions of the software.
Register
Register name
Description
Table 128:
Advanced registers
summary