Changing the parameters within a sequence
To change the parameter set for one image, it is not necessary to modify the
settings for the entire sequence. The image can simply be selected via the
ImageNo
field and it is then possible to change the corresponding IIDC
V1.31 registers.
Points to pay attention to when changing the
parameters
Note
•
If the
ApplyParameters
flag is used when setting the
parameters, all not-configured values are set to default
values. As changing a sequence normally affects only
the value of a specific register, and all other registers
should not be changed, the
ApplyParameters
flag may
not be used here.
•
The values stored for individual images can no longer
be read.
•
If the camera is switched into
sequence mode
, the
changes to the IIDC V1.31 registers for the image spec-
ified in
ImageNo
take immediate effect.
•
Sequence mode requires special care if changing image
size and frame rate related parameters. This is because
these changes not only affect settings in the camera
but also require corresponding settings in the receiving
software in the PC (e.g. FirePackage).
Caution
•
Incorrect handling may lead to
image corruption
or
loss of subsequent images
.
•
Please ask for detailed support if you want to use
this feature.