Ping Polling Commands
©2008 Allied Telesis Inc. All rights reserved.
63.12
AlliedWare Plus
TM
Operating System Software Reference C613-50003-00 REV E
Software Version 5.2.1
sample-size
This command sets the total number of pings that the polling instance inspects when
determining whether a device is unreachable. If the number of pings specified by the
fail-
count
command go unanswered within the inspected sample, then the device is declared
unreachable.
If the numbers set in this command and
fail-count
command are the same, the unanswered
pings must be consecutive. If the number set by this command is greater than that set with the
fail-count
command, a device that does not always reply to pings may be declared unreachable.
You cannot set this command’s value lower than the
fail-count
value.
The polling instance uses the number of pings specified by the
up-count
command to
determine when a device is reachable.
The
no
parameter resets this command to the default value.
Syntax
sample-size <1-100>
no sample size
Mode
Ping poll mode.
Examples
To set the sample-size to 50, use the command:
awplus(config-ping-poll)#
sample-size 50
To reset sample-size to the default of 5, use the command:
awplus(config-ping-poll)#
no sample-size
Related Commands
critical-interval
fail-count
normal-interval
ping-poll
show ping-poll
timeout
up-count
Parameter
Description
<1-100>
Number of pings that determines critical and up counts.
Default:
5
Содержание AlliedWare Plus 5.2.1
Страница 8: ...65 Stacking Commands Introduction 65 2 Appendix l Command List ...
Страница 10: ......
Страница 218: ......
Страница 376: ......
Страница 726: ......
Страница 806: ......
Страница 1006: ......
Страница 1056: ......
Страница 1235: ...Stacking Reference This part includes the following chapters Chapter 64 Stacking Introduction Chapter 65 Stacking Commands ...
Страница 1236: ......