Ping Polling Commands
©2008 Allied Telesis Inc. All rights reserved.
63.20
AlliedWare Plus
TM
Operating System Software Reference C613-50003-00 REV E
Software Version 5.2.1
up-count
This command sets the number of consecutive pings that the polling instance must receive a
reply to before classifying the device reachable again.
The
no
parameter resets the up count to the default of 30.
Syntax
up-count <1-100>
no up-count
Mode
Ping polling mode
Examples
To set the upcount to 5 consecutive pings, use the command:
awplus(config-ping-poll)#
up-count 5
To reset the upcount to the default value of 30 consecutive pings, use the command:
awplus(config-ping-poll)#
no up-count
Related Commands
critical-interval
fail-count
normal-interval
ping-poll
sample-size
show ping-poll
timeout
Parameter
Description
<1-100>
Number of replied pings before an unreachable device is classified as
reachable.
Default:
30