Water Fill Does Not Stop At Proper Level
WASH, RINSE STATUS lights flash 1 or 2 times (Pressure Sensor or Fill Error), or remain on continuously (Overflow)
NOTE: The Auto Fill feature may add more water even when the Small, Medium or Large Load Sizes are selected.
Is there a Pressure
Sensor error? (WASH,
RINSE LEDs flash 1
time)
Is there an overflow
error? (WASH, RINSE
LEDs on continuously)
No
Check for restricted
or clogged pressure
bulb or hose. If
clear replace sensor.
Yes
Is there an air leak
in pressure hose?
No
Check for a leak in
the mixing valve.
Yes
Is mixing valve
inoperative?
No
Replace hose or
pressure bulb.
Yes
Was there a siphoning
action started in
washer causing water
to be siphoned from
washer during cycle
due to end of drain
hose being lower than
cabinet top of washer?
No
Test valve and
replace if
inoperative. Refer to
Mixing Valve Solenoid
Test.
Yes
Does drain hose fit
tight in standpipe or
drain?
No
Install 562P3 Siphon
Break Kit.
Yes
Is there water in
pressure hose?
No
Provide an air gap
around drain hose and
drain receptacle.
Yes
Is there broken,
loose, shorted or
incorrect wiring?
No
Blow air through hose
to remove water or
replace hose.
Yes
Refer to appropriate
wiring diagram.