Factory Test Procedure Quick Reference Chart
Number
Display
(LEDs lit)
Motor
Valves
Lid
Pump
Exit
Step
10
In Software
Version 3
and higher
this is skip-
ped.
Wash, Spin
Delicate Long
Stroke Agitate
Cycle Output
Locked
Off
1
Long Stroke
Agitate
11
In Software
Version 3
and higher
this is skip-
ped.
Rinse, Spin
Delicate Short
Stroke Regular
Agitate
None
Locked
Off
1
Short Stroke
Agitate
12
Refer to
Factory Spin
Profile
None
Locked
On
1
Factory Spin
13
Wash, Rinse
always on
Spin, Lid
Lock when
unbalance
switch press-
ed
Off
None
Unlocked
Off
14 and then 1
Unbalance
Switch Test
14
Rinse, Spin
and Lid Lock
when lid
locked
Off
Hot, Cold, Cy-
cle output
Unlocked
On
1 and then 4
Breakaway
15
None
Off
None
Unlocked
Off
13
Power Down
Table 1
Exit Column Key
1
Exit by pressing Start/Pause button
2
Exit by fill level satisfaction
3
Exit when all selections are pressed
4
Exit when lid is unlocked
5
Exit when temperature reaches 104°F [40°C]
6
Exit when step timed out
7
Exit when lid locks
8
Exit when overflow level is reached
Table 2
continues...
Exit Column Key
9
Exit when washtub is empty
10
Exit when lid is closed
11
Exit when lid is opened
12
Exit when drive communication is established
13
Exit when machine unpowered
Table 2
Troubleshooting Diagnostics
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
11
Part No. 204666ENR1
Содержание ZWN43RSN115CW01