201143
17
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
General Troubleshooting
4. No Cold Water
There is no cold
water.
Is the water
supply faucet
closed?
Open faucet.
Yes
Is the cold
water fill hose
kinked?
Straighten or
replace hose.
Yes
Is the mixing valve
screen or screen in
outer end of fill hose
nearest water supply
faucet clogged?
No
Disconnect
cold fill hose
and clean or
replace screen.
Yes
Is cold water
mixing valve
solenoid
inoperative?
Test
solenoid
and
replace if
necessary.
Yes
Yes
Is temperature
switch
inoperative?
Test switch
and replace if
inoperative.
Yes
Is pressure
switch
inoperative?
Test switch.
Must have
continuity from
terminal 1 to 2
when empty or
1-3 when full.
Replace if
inoperative.
Yes
Is pressure
hose
clogged?
Remove and
clean or
replace hose.
Yes
No
Is there
broken, loose
or incorrect
wiring?
Refer to
appropriate
wiring
diagram.
Yes
No
TLW410S
No
No
No
Is unit plugged in
and power
available to outlet?
Check plug
and reset
circuit
breaker.
No
No
No
Yes
Is
timer/control
inoperative?
Test for
continuity
through timer
circuits (refer to
wiring diagram)
or test control
and replace if
inoperative.