Electrical Wiring
Important - Although the heat pump is electrically isolated from the rest of the unit, this only
prevents the passage of electricity to or from the pool water. Grounding the unit is still
required to protect yourself from short circuits inside the unit. Make for adequate ground
connection.
Check if the electrical mains voltage corresponds with the operating voltage of the heat pump prior to
hooking up the unit.
It is recommended to use a separate fuse (C-curve) as well as adequate wiring (see table below). Connect
the electrical wires with the terminal block labelled ‘TO POWER SUPPLY’.
Next to this connection, there is a second terminal block labelled ‘TO PUMP’, to which the pool pump
(max. 5A/240V) or an electrical relay for a filtration pump can be connected. This connection makes it
possible to control the pool pump operation with the heat pump.
However, we do not recommend that you wire the pool circulation pump to the heat pump. Run
separate power supplies to the heat pump and the pool circulation pump. This allows the pool
circulation pump to be put on a time clock and operated for the required time to give adequate
filtration for the pool and also the pool circulation pump can be manually operated when
required to backwash the filter etc.
Model
Voltage (V)
Fuse (C-curve)
Max current (A)
Cable section*
ALLPH90R410 - INV
220-240V
20
8.62
2.5 mm2
ALLPH120R410 - INV
220-240V
20
13
2.5 mm2
ALLPH160R410 - INV
220-240V
20
13.96
2.5 mm2
ALLPH190R410 - INV
220-240V
32
21.17
4 mm2
* For a maximum cable length of 50m