background image

 

 
 

 
 
 
 
 

 

 

 

 

Alliance Warranty 2020 – V1 
 

ALLIANCE INVERTER SWIMMING POOL  

HEAT PUMP WARRANTY CARD 

 

ONE YEAR LIMITED WARRANTY ON UNIT 

THREE LIMITED WARRANTY ON COMPRESSOR 

FIVE YEAR LIMITED WARRANTY ON HEAT EXCHANGER 

 

PLEASE READ CAREFULLY BEFORE FILLING IN AND STORING IN A SAFE PLACE 

 

Terms of our comprehensive Warranty are as follows

 

1. 

Subject to the stated terms and conditions, 
warranty is given to the purchaser in respect of 
the Alliance Heat Pump, Model No and Serial No. 

as listed on the back of this card for 12 months on 
the unit, 12 months on the heat exchanger and 36 

months on the compressor, from date of 
installation. This warranty is subject to servicing 
being maintained in line with the servicing 

standard as set out in the schedule on the back of 
this warranty card. Should the equipment not be 

serviced as per the schedule, this warranty will 
become null and void.  
 

5. 

This warranty will lapse if any repairs are carried 
out by any dealer other than any dealer authorised 
by Alliance. An authorised dealer is a company that 

deals with Fourways Airconditioning.   The warranty 
will also lapse if any unauthorised alteration to this 

warranty card is effected.  

2. 

This warranty covers defects caused by original 
manufacturing faults, defective manufacturing 

assembly, or faulty material. It does not cover 
defects as a result of incorrect installation but is a 
parts only warranty and excludes labour costs. It 

also does not extend to repairs, replacement of 
parts, maintenance or service necessitated by 

normal wear and tear, incorrect operation, failure 
to properly maintain, improper cleaning methods, 
infestation by insects or vermin, maltreatment of 

the product, misuse, connection to an incorrect 
voltage, power surges, damage caused by 

lightning, accidents, flooding, fire, Acts of God, 
public disturbances, accidental damage, rust and 

corrosion, work carried out by persons other than 
an authorised Alliance dealer, or being incorrectly 
sized for the application required, according to 

authorised dealer’s recommendations. In cases of 
dispute, repairs, replacement of spare parts, 

maintenance and service shall be deemed to be 
beyond the scope of this warranty unless the 
purchaser is able to prove to the contrary. 

6. 
 

 
 
 

 
7. 

 
 
8. 

 

This warranty is not transferable and is only valid in 
South Africa.  It is valid only for the original 

purchaser of the Product. This purchaser will be the 
person who owns the machine once installation is 
completed. 

 
 

Any repairs carried out under this warranty will not 
extend the period of the warranty in any way.  
 

Neither Alliance nor authorised Alliance service 
agents shall be responsible at any time during or 

after the period of this warranty for any loss or 
damage of whatsoever nature, whether general, 

special or consequential which may be caused or 
sustained by the purchaser, whether arising from, 
connected with or relating to any defect, fault or 

lack in the Product, whether such inability is 
complete or partial. 

 

3. 

During the period of the warranty, faults covered 
by the warranty will be repaired as per the 

schedule by the installing dealer (or other 
authorised Alliance dealer), with only the cost of 
the parts covered. These will be supplied by the 

relevant Alliance Service Centre.  

9. 

This warranty replaces all common law and other 
rights or remedies which may otherwise be 

available to the purchaser.  

 
 

 
 

22

 

Содержание ALLPH120R410-INV

Страница 1: ...w INV Thank you very much for purchasing our product Before using your heat pump please read this manual carefully and keep if for future reference The manufacturers of Alliance Heat Pumps employ over 300 senior engineers and operate 31 approved test laboratories guaranteeing the innovation and high quality of Alliance products ...

Страница 2: ...6 Electrical wiring 7 Initial start up of unit 8 Condensation 8 Controller operation 9 16 Error code list 17 18 PC Board wiring diagram 19 Maintenance and inspection 20 Appendix 21 Warranty 22 24 Contact Information 25 N B This Installation Manual is the property of Alliance Heat Pumps and all rights of copyright are reserved It may not be reproduced or used for any other purpose without written p...

Страница 3: ... only be repaired by qualified personnel or an authorized dealer Maintenance and operation must be carried out according to the recommended time and frequency as stated in this manual Use genuine standard spare parts only Failure to comply with these recommendations will invalidate the warranty Swimming Pool Heat Pump Unit heats the swimming pool water and keeps the temperature constant Our heat p...

Страница 4: ...urrent range A 1 29 6 86 1 3 13 1 Max Current A 8 62 13 96 Compressor quantity 1 1 Compressor type Rotary Rotary Refrigerant R410a Fan quantity 1 1 Fan power input W 100 120 Fan rotary speed RPM 500 750 600 750 Fan direction Horizontal Horizontal Noise dB A 40 44 Water connection mm 50 50 Nominal water flow m3 h 2 0 5 3 Water pressure drop max kPa 4 0 5 Unit net dimensions L W H mm 1003 396 767 11...

Страница 5: ...Current range A 1 3 13 1 1 6 17 1 Max Current A 13 96 21 17 Compressor quantity 1 1 Compressor type Rotary Rotary Refrigerant R410A Fan quantity 1 1 Fan power input W 120 120 Fan rotary speed RPM 600 750 600 900 Fan direction Horizontal Horizontal Noise dB A 44 45 Water connection mm 50 50 Nominal water flow m3 h 5 3 6 6 Water pressure drop max kPa 5 6 Unit net dimensions L W H mm 1117 430 868 111...

Страница 6: ...L 1117 mm H 868 mm W 447 mm Dimensions Alliance Inverter 9 12kw Alliance Inverter 16 19kw Alliance Inverter 16Kw Alliance Inverter 19Kw A 400 470 L 1003 mm H 767 mm W 410 mm 3 4 ...

Страница 7: ...lock air inlet outlet These locations deny the unit of a continuous source of fresh air which reduces its efficiency and may prevent adequate heat delivery How Close To Your Pool Normally the pool heat pump is installed within 7 5 meters of the pool The longer the distance from the pool the greater the heat loss from the piping For the most part the piping is buried Therefore the heat loss is mini...

Страница 8: ... noise 4 Always keep the heat pump in upright position If the unit has been tilted you should wait for at least 24 hours before turning it on Installation of a check valve When using automatic chlorine and pH dosage systems it is of extremely import to protect the heat pump from high concentrations of these chemicals that could corrode the heat exchanger Therefore such systems should add the chemi...

Страница 9: ...elled TO PUMP to which the pool pump max 5A 240V or an electrical relay for a filtration pump can be connected This connection makes it possible to control the pool pump operation with the heat pump However we do not recommend that you wire the pool circulation pump to the heat pump Run separate power supplies to the heat pump and the pool circulation pump This allows the pool circulation pump to ...

Страница 10: ...to protect control circuit components and to eliminate restart cycling and contactor chatter This time delay will automatically restart the unit approximately 3 minutes after each control circuit interruption Even a brief power interruption will activate the solid state 3 minute restart delay and prevent the unit from starting until the 3 minute countdown is completed Power interruptions during th...

Страница 11: ...er and exit the mute mode with one click Mode key It is used to switch the unit mode temperature setting and parameter setting On off key It is used to carry out start up shutdown cancel current operation and return to the last level of operation Up key It is used to page up and increase variable value Down key It is used to page down and decrease variable value Clock key It is used as user clock ...

Страница 12: ...f Timing symbol It will display after the user sets the timing and multiple timing intervals can be set Water outlet symbol When the axillary display area displays the water outlet temperature the light is on Water inlet symbol When the main display area displays the water inlet temperature the light is on Locking key symbol When the keyboard is locked it is on Fault symbol In case of unit fault i...

Страница 13: ...ay as follows Operations are the same as under ON OFF main interface Change mode Under the main interface Short press to switch the unit among heating cooling and automatic mode When there is no operation within 1 minute it will display with half screen off When there is no operation within 15 minutes it will display with full screen off Keep long press of for 0 5 s to enter ON OFF interface Autom...

Страница 14: ...e the unit won t work under a new mode until defrosting is completed Clock setting System time setting Notes Under the clock setting interface if there is no operation for 20 s the system will automatically memorize use s settings and return to the main interface if short press during any operating steps the changes will not be saved and return to the main interface Defrosting state Flashing Minut...

Страница 15: ...The wire controller can set up a two stage timing function Timer ON1 OFF1 Timer ON2 OFF2 Select ON 1 OFF1 ON 2 OFF timer setting interface Temperature setting Notes Under the temperature setting interface if short press the system will return to the main interface without any changes saved If there is no operation for 5 s or short press Setting the Timer ON OFF function Set the ON OFF timer as bel...

Страница 16: ... example Short press to save the change and return to the main interface Silent setting One click silent function Notes 1 If one click silent and timing silent are started at the same time short press for canceling one click silent and quitting the timing silent for this time 2 At night the user can start one click silent or timing silent function to reduce the noise Flashing short press 13 14 ...

Страница 17: ...n silent Keep long press of for 2 s Short press or Setting and cancelling the silent function Notes 1 When the silent icon is illuminated The timing mute has been set but it s not under silent status 2 When the silent icon flash It s under the silentstatus 3 When the silent icon disappear The timing silent is not set Keyboard lock To avoid others misoperation please lock the wire controller after ...

Страница 18: ...der silent status 2 When the silent icon flashes It s under the silent status 3 When the silent icon not there The timing silent is not set 4 8 Keyboard lock To avoid others misoperation please lock the wire controller after completing the setting Notes 1 Under the locked screen interface only unlocking operation is available and the screen will be illuminated after other operations conducted 2 Un...

Страница 19: ...ur F26 The equipment load is too large PFC fault F27 The PFC circuit protection Check the PFC switch tube short circuit or not IPM Over heating F15 The IPM module is overheat Check and adjust the current measurement Weak Magnetic Warning F16 Compressor magnetic force is not enough Inv Input Out Phase F17 The input voltage lost phase Check and measure the voltage adjustment IPM Sampling Cur F18 IPM...

Страница 20: ...ection Check the pressure switch and cold circuit Flow Switch Prot E03 No water little water in water system Check the pipe water flow and water pump Waterway Anti freezing Prot E05 Water temp or ambient temp is too low Inlet and outlet temp too big E06 Water flow is not enough and low differential pressure Check the pipe water flow and whether water system is jammed or not Anti freezing Prot E07 ...

Страница 21: ...PC Board wiring diagram Wire control interface diagram and definition V R T A B G Terminal Function V 12V power R Not used T Not used A 485A B 485B G GND power 19 ...

Страница 22: ...it are operational and pay special attention to the operation pressure of the refrigerant system Check the power supply and cable connections regularly Should the unit begin to function abnormally or should you notice a smell from an electrical component arrange for timely repair or replacement Winterizing make sure to drain all the water from the heat pump and other systems in order to prevent fr...

Страница 23: ...id a hazard 5 Directive 2002 96 EC WEEE The symbol depicting a crossed out waste bin that is underneath the appliance indicates that this product at the end of its useful life must be handled separately from domestic waste must be taken to a recycling centre for electric and electronic devices or handed back to the dealer when purchasing an equivalent appliance 6 Directive 2002 95 EC RoHs This pro...

Страница 24: ...aintain improper cleaning methods infestation by insects or vermin maltreatment of the product misuse connection to an incorrect voltage power surges damage caused by lightning accidents flooding fire Acts of God public disturbances accidental damage rust and corrosion work carried out by persons other than an authorised Alliance dealer or being incorrectly sized for the application required accor...

Страница 25: ...ear as per the schedule below or more frequently as advised by authorised Alliance installer 3 Equipment must be serviced by an authorised Alliance dealer 4 Should the equipment be installed in very dusty or dirty environments servicing should be done every three months or a minimum of twice a year depending on environment The installing dealer will advise you as to the servicing intervals require...

Страница 26: ...17 Parts and warranty details Controller PC boards Capacitor Relays Sensors 2 Year warranty Part only after 1st year High pressure low pressure switch 2 Year warranty Part only after 1st year Water flow switch 2 Year warranty Part only after 1st year EEV Solenoid 2 Year warranty Part only after 1st year Titanium heat exchanger 5 Year warranty Part only after 1st year Compressor 5 Year warranty Par...

Страница 27: ...25 ...

Отзывы: