58
60549
Section 7 Gas Burner Conversion Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
62. INSTALLING THE NO. 401P3 KIT
a. Apply thumb pressure to the right side of access
door. Refer to Figure 40. When door opens,
move door to the left to disengage from door
supports.
b. Disconnect igniter wires at quick disconnect
blocks. Refer to Figure 41.
c. Remove hex head screw holding burner tube
and igniter in place. Refer to Figure 41.
d. Carefully move burner tube toward rear of
dryer, far enough to permit removal of burner
orifice spud from gas valve.
NOTE: Tab on burner tube may have to be
removed from slot in burner housing to obtain
enough clearance.
e. Turn burner orifice spud out of gas valve and
install No. 58755 L.P. Burner Orifice Spud
(metal stamped #55). Torque new burner
orifice spud to 30 inch-pounds (3.4 N-m).
f. Reinstall burner tube, tighten hex head screw
firmly and reconnect igniter leads.
g. Remove vent screw and install No. 58754
Block-Open Plug. Refer to Figure 41.
h. Install No. 60517 “Valve Converted to L.P.
Gas” Sticker to top side of gas valve so it covers
the gas valve part number.
i. Sign and date each of the two No. 60520 L.P.
Gas Stickers. Install one of the No. 60520 L.P.
Gas Stickers over the top three lines of the old
sticker on rear of cabinet. Refer to Figure 42.
Then place the second sticker over the top three
lines of the old sticker located on backside of
access door. Refer to Figure 40.
j. Apply the No. 60515 Conversion Plate to the
inside of the loading door opening above the
nameplate. Refer to Figure 43.
k. Turn the gas line shut-off valve handle to the
open position and connect electrical service.
Refer to Figure 41.
l. Check gas valve pressure as follows:
(1) Remove pressure tap pipe plug. Refer to
(2) Connect a “U” tube manometer (or similar
pressure gauge) to the pressure tap. Refer
(3) Start dryer, pressure should be 10 ± 1.5
inches (25.4, ± 3.8 cm). Refer to Figure 41.
Figure 40
To reduce the risk of electrical shock,
disconnect electrical power to the dryer
before servicing the dryer.
WARNING
DRY951S
APPLY
PRESSURE
HERE
SUPPORT
ACCESS
DOOR
To reduce the risk of fire and explosion,
reach in through access door opening and
turn the gas line shut-off valve handle to
the closed position. Refer to Figure 41.
WARNING