Section 8 Service Procedures Unique to Electronic Control Model Dryers
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
80. SYMPTOM: BLOWN FUSE OR TRIPPED CIRCUIT BREAKER
Fuse blown or tripped breaker?
NO
YES
Unplug power cord and disconnect
wires from terminals “P3” and
“COM”. Take resistance reading
between terminals.
Reset breaker or replace fuse.
Does fuse or breaker blow
immediately upon plugging in
power cord?
Does fuse or breaker blow
immediately after motor starts?
YES
NO
*166 Ohms ± 30% between “P3”
and “COM” terminals.
Replace
control.
YES
NO
Check for broken, loose or
incorrect wiring.
Wiring okay?
YES
Correct
wiring.
NO
Recheck from beginning. If
problem persists, replace control.
Check motor and
motor switch.
Does fuse or breaker blow 15
seconds after motor starts?
YES
Check heater circuit for
shorted, broken, loose or
incorrect wiring.
Recheck from
beginning.
NO
*This measurement should be made with a digital Multi-Meter set at 200 Ohm scale for best precision.