60549
1
© Copyright 2002, Alliance Laundry Systems LLC
All rights reserved. No part of the contents of this book may be reproduced or transmitted in any form or by any means without
the expressed written consent of the publisher.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Table of Contents
Section 1 – Safety Information
Locating an Authorized Servicer ............................4
Customer Service ....................................................5
Nameplate Location ................................................5
Model Identification ................................................6
How Your Dryer Works ..........................................7
1. Motor Does Not Run ........................................9
2. Motor Overload Protector Cycles
Repeatedly ......................................................10
3. Motor Runs But Cylinder Does Not Turn ......10
4. Motor Does Not Stop .....................................10
5. Heater Assembly Does Not Heat or Burner
Does Not Ignite ..............................................11
6. Igniter Does Not Glow (Gas Supply Sufficient)
– Gas Models .................................................12
7. Burner Ignites and Goes Out Repeatedly
– Gas Models .................................................12
8. Igniter Glows But Burner Does Not Ignite
– Gas Models .................................................12
9. Heater Assembly or Burner Shuts Off
Prematurely ....................................................13
10. Heater Assembly Or Burner Repeatedly Cycles
Off On Limit Thermostat ...............................13
11. Heater Assembly Or Burner Does
Not Shut Off ...................................................14
12. Clothes Do Not Dry .......................................14
13. Timer Does Not Advance In Automatic Cycle
(Mechanical Timer Models Only) ..................15
14. Clothes are too Hot When Removed
from Dryer ......................................................15
15. Motor Mounting Bracket To Motor ...............17
16. Motor Mounting Bracket to Exhaust Fan Cover
(Gas and Electric Models with painted exhaust
fan cover – ground wire not used on unpainted
covers) ............................................................17
17. Neutral at Terminal Block to Terminal Block
Bracket and Front Terminal Block Bracket to
Control Housing (Electric Models Only) .......18
18. Power Cord to Terminal Block Bracket and from
Terminal Block Bracket to Control Housing.
Wall Receptacle Polarity Check (Gas Models
Only) ..............................................................19
19. From Terminal Block Bracket to Timer
Mounting Bracket to Dryer Cabinet Top. Timer
Mounting Bracket to Graphic Panel
(Mechanical Timer Model Dryers Only) .......20
20. From Terminal Block Bracket to Dryer Cabinet
Top to Electronic Control to Graphic Panel
(Electronic Control Model Dryers) ................20
Section 5 – Service Procedures
To Test Timer Contact Points .........................24
24. Temperature Switch .......................................25
To Test Temperature Switch...........................25
25. Signal Control ................................................25
To Test Signal Control....................................25
26. Start Switch ....................................................25
To Test Start Switch (Push or Rotary Type)...25
27. Graphic Panel .................................................25
28. Lint Filter .......................................................26
29. Loading Door .................................................26
30. Inner and Outer Door Panels and
Door Handle ...................................................27
31. Door Striker ...................................................27
32. Door Seal .......................................................27
33. Front Panel and Panel Seal ............................28
34. Door Switch ...................................................28
To Test Door Switch .......................................29
35. Striker Catch ..................................................29
36. Door Hinge ....................................................29
37. Hold-Down Clips and Guide Lugs ................29
38. Burner System Operation (Gas Models) ........30
39. Ignition System Features (Gas Models) .........31
40. Burner System Components – Gas Models ...32
To Test Igniter (Gas Models)..........................33
To Test Sensor (Gas Models) .........................34
To Test Cycling or Limit Thermostat .............35
43. Heater Assembly ............................................36
44. High or Low Thermostat or Thermostat and
Heater or Thermistor ......................................37
To Test Thermostat Heater .............................37
To Test Thermal Fuse (Electric Models) ........37
To Test Heater Assembly (Electric Models) ..38
45. Front Air Duct ................................................38
(continued)
Содержание AE4113
Страница 9: ...8 60549 Section 2 Introduction Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Страница 17: ...16 60549 Section 3 Troubleshooting Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Страница 125: ...124 60549 Section 10 Wiring Diagrams Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...