Section 8 Service Procedures Unique to Electronic Control Model Dryers
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
75. ELECTRICAL REQUIREMENTS
(Gas Dryers)
120 Volt, 60 Hertz, with 3-Prong Grounding Plug
NOTE: The wiring diagram is located inside the
control hood.
a. The dryer is designed to be operated on a
separate branch, polarized, three-wire,
effectively grounded, 120 Volt, 60 Hertz, AC
(alternating current), circuit protected by a 15
ampere fuse, equivalent fusetron or circuit
breaker.
b. The three-prong grounding plug on the power
cord should be plugged directly into a polarized
three-slot effectively grounded receptacle rated
110/120 Volts AC (alternating current) 15
Amps. Refer to Figure 57 for determining
correct polarity of the wall receptacle.
c. DO NOT OPERATE OTHER APPLIANCES
ON THE SAME CIRCUIT. DO NOT
OVERLOAD CIRCUITS! Refer to Figure 58.
Figure 57
To reduce the risk of fire, electric shock or
personal injury, all wiring and grounding
MUST conform with the latest edition of the
National Electrical Code ANSI/NFPA 70 or
the Canadian Electrical Code, CSA C22.1,
and such local regulations as might apply. It
is the customer’s responsibility to have the
wiring and fuses checked by a qualified
electrician to make sure the laundry room
has adequate electrical power to operate the
dryer.
W035
WARNING
115±12
V.A.C.
0
V.A.C.
115±12
V.A.C.
DRY1067S
STANDARD
120 VOLT,
60 HERTZ,
3-WIRE
EFFECTIVELY
GROUNDED
CIRCUIT
GROUND
NEUTRAL
L1
NEUTRAL
SIDE
ROUND
GROUNDING
PRONG
NOTE: A qualified electrician should check the polarity of
the wall receptacle. If a voltage reading is measured other
than that illustrated, the qualified electrician should correct
the problem.
Figure 58
To reduce the risk of an electric shock or
fire, DO NOT use an extension cord or an
adapter to connect the dryer to the electrical
power source.
W037
WARNING
DRY1066S
DO NOT
OVERLOAD CIRCUITS