69
|
P a g e
ELECTRICAL
(CONTINUED)
Inverter
Overview
(Continued)
Reverse
battery
protection
Reverse
battery
protection
has
been
added
to
the
inverter
to
protect
the
equipment
in
the
event
that
the
positive
and
negative
terminals
of
the
battery
are
incorrectly
connected
to
the
inverter.
Unlike
some
other
inverters
on
the
market,
there
is
not
a
time
delay
associated
with
the
reverse
battery
protection.
In
the
event
that
the
inverter
is
reverse
wired
it
will
not
turn
on.
Over
‐
load
protection
In
order
to
protect
the
inverter
from
over
‐
load
conditions
the
power
draw
is
continually
measured,
and
should
it
exceed
the
rated
output
power,
the
inverter
will
automatically
shut
down
and
display
the
error
code
corresponding
to
an
over
‐
load
error.
This
is
a
required
feature
in
all
UL
safety
certified
inverters.
For
additional
protection
the
PD1200
Series
inverter
includes
a
15A
circuit
breaker
on
the
output
to
limit
power
that
is
passed
through
from
the
AC
Input.
Short
circuit
protection
In
any
power
system,
a
sustained
short
circuit
can
cause
hazardous
conditions
potentially
resulting
in
over
‐
heating
and
fire.
To
avoid
these
conditions
the
inverter
has
been
designed
with
short
circuit
protection.
It
will
detect
any
large
current
spikes
caused
by
a
short
circuit
and
shutdown
immediately
to
avoid
damaging
the
inverter
and
output
wiring.
Over
temperature
protection
A
required
feature
for
all
UL
safety
certified
inverters,
over
temperature
protection
is
designed
into
every
PD1200
Series
inverter.
When
the
internal
temperature
of
the
inverter
gets
too
high
due
to
poor
ventilation
or
high
ambient
temperature
the
inverter
will
shut
down.
The
output
will
automatically
turn
back
on
when
the
internal
temperature
returns
to
safe
operating
temperatures.
Thermally
controlled
variable
speed
fan
Using
technology
that
is
found
in
all
Progressive
Dynamics
Converters,
the
PD1200
Series
Inverter
employs
a
thermally
controlled
variable
speed
fan.
This
fan
will
only
turn
on
when
the
inverter
is
operating
at
a
warmer
than
normal
temperatures.
Furthermore,
when
it
does
turn
on,
the
speed
of
the
fan
is
smoothly
controlled
to
only
run
as
fast
as
necessary
to
keep
the
inverter
within
safe
operating
temperatures.
This
is
designed
to
minimize
disruptive
audible
noise.
Содержание Paradigm
Страница 1: ...Obsessed with providing the best RV ownership experience OWNER S GUIDE Version 2 4 20 ...
Страница 103: ...97 P a g e AWNINGS CONTINUED Awning Component Breakdown GO TO TOP ...
Страница 126: ...120 P a g e PLUMBING AND UTILITIES CONTINUED Centralized Docking Station Continued Connecting to City Water GO TO TOP ...
Страница 127: ...121 P a g e PLUMBING AND UTILITIES CONTINUED Centralized Docking Station Continued Winterizing GO TO TOP ...
Страница 128: ...122 P a g e PLUMBING AND UTILITIES CONTINUED Centralized Docking Station Continued Winterizing Continued GO TO TOP ...
Страница 129: ...123 P a g e PLUMBING AND UTILITIES CONTINUED Centralized Docking Station Continued Winterizing Continued GO TO TOP ...
Страница 130: ...124 P a g e PLUMBING AND UTILITIES CONTINUED Rinsing Holding Tanks Tank Flush GO TO TOP ...
Страница 131: ...125 P a g e PLUMBING AND UTILITIES CONTINUED Rinsing Holding Tanks Tank Flush Continued GO TO TOP ...