dS
Brownout/voltage
configuration error:
Unexpected supply
voltage.
Check the harness
connections be-
tween the user con-
trol and the output
board. If the user
control was re-
placed, set dips-
witch #1 to the
same setting as the
previous control. If
reworking the ma-
chine to use a dif-
ferent supply volt-
age, the dip switch
#1 setting may need
to be changed. If
the dip switch #1
setting is changed,
power down ma-
chine, power up
and try again.
Er
id
Board ID error: In-
correct replacement
control.
Terminate cycle.
Replace user con-
trol or output board
with correct part.
Power down ma-
chine to clear.
Er
bS
Board shorted er-
ror: Hardware error.
Replace output
board. Power down
machine to clear.