Secondary Coil – Terminals 4
& 5
1325 ± 230 Ohms
Table 1 Coil Tolerance Readings
NOTE: If meter registers any other readings than those
listed above, the respective coil(s) should be replaced.
Sensor Check (Gas Models)
1. While supporting the access panel, remove two screws from
bottom edge of access panel.
2. Gently lower the access panel to disengage locators from bot-
tom edge of front panel.
3. Close main gas shut-off valve. Refer to
.
4. Remove wires from sensor terminals.
5. Set test meter to read Ohms and put meter probes on sensor
terminals. Meter should read “zero” Ohms. If meter registers
an Ohm reading of any amount, replace sensor.
Igniter Check (Gas Models)
1. While supporting the access panel, remove two screws from
bottom edge of access panel.
2. Gently lower the access panel to disengage locators from bot-
tom edge of front panel.
3. Close main gas shut-off valve. Refer to
.
4. Disconnect igniter wires at disconnect block.
5. Set test meter to read Ohms and put meter probes on terminals
of igniter wires.
6. Meter should read between 45 – 200 Ohms. Refer to
.
NOTE: If meter does not read appropriate Ohms, then
replace the igniter.
IMPORTANT: Always examine all wires, terminals and
connectors to be sure wiring is correct before replac-
ing any components.
1.
Igniter and Bracket
2.
Attaching Screw
3.
White Ceramic Portion
Figure 13
Thermal Fuse Electric (Models)
1. While supporting the access panel, remove two screws from
bottom edge of front access panel.
2. Gently lower the access panel to disengage panel locators
from bottom edge of front panel.
3. Label and disconnect wires from thermal fuse.
NOTE: Refer to wiring diagram when rewiring ther-
mal fuse.
4. Set multimeter to read Ohms. Apply meter probes to thermal
fuse terminals. Multimeter should read 0 Ohms. If the meter
does not show any reading (infinite Ohms), then the fuse is
open. If the fuse is open, then replace BOTH the thermal fuse
and the limit thermostat.
Heater Assembly (Electric Models)
1. While supporting the access panel, remove two screws from
bottom edge of access panel.
2. Gently lower the access panel to disengage panel locators
from bottom edge of front panel.
3. Disconnect wires from heater assembly.
NOTE: Refer to wiring diagram when rewiring heater
assembly.
4. Set meter to read Ohms. Apply meter probes to the heater as-
sembly terminals. Meter should read as follows: (Cold
Ohms).
Element Col-
or Code
KW
Voltage/Hz.
Resistance
Reading
Table continues...
Test Procedures
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
49
Part No. D515517ENR3