Burner Ignites and Goes Out Repeatedly (Gas Dryer Models)
Is exhaust system
improper or
inadequate?
Is weather hood
flapper restricted?
No
Refer to Installation
Instructions
(supplied with unit)
for exhaust
requirements.
Yes
Is burner heat
holding sensor
contacts open?
No
Refer to Installation
Instructions
(supplied with unit)
for exhaust
requirements.
Yes
Is gas supply
insufficient?
Yes
Replace sensor or
correct gas supply
problem.
No
Is igniter cracked?
No
Check gas supply and
pressure. Make sure
gas shut-off valve is
turned on.
Yes
Are gas valve coils
inoperative or
intermittent?
No
Replace igniter and
bracket.
Yes
Check coils and
replace appropriate
coils. Refer to Dryer
Test Procedures
section.
Yes
Troubleshooting Flowcharts
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
23
Part No. D515517ENR3
Содержание ZDE3SRGS173CW01
Страница 2: ......