Timer/Electronic Control Does Not Advance in Automatic Cycle
Is cycling thermostat
inoperative?
Timer models: Is
resistor inoperative?
No
Test thermostat and
replace if
inoperative.
Yes
Heater assembly does
not heat or burner
does not ignite?
No
Test resistor and
replace if
inoperative.
Yes
Heater assembly or
burner cycles off
prematurely?
No
Refer to Dryer
Heating Assembly Does
Not Heat or Burner
Does Not Ignite
paragraph.
Yes
Is exhaust system
improper or
inadequate?
No
Refer to Dryer Heater
Assembly or Burner
Shuts Off Prematurely
paragraph.
Yes
Is large load drying?
No
Refer to Installation
Instructions
(supplied with unit)
for exhaust
requirements.
Yes
Is wiring broken,
loose or incorrect?
No
Timer will not
advance until the
load is almost dry.
Yes
Timer models: Is
timer motor
inoperative?
No
Refer to wiring
diagram.
Yes
Electronic control:
Is control
inoperative?
No
Select a drying cycle
and activate start
switch. Rotate timer
knob until signal
sounds. Release timer
knob. Signal should
stop within ten
minutes. If not,
replace time
Yes
Are seals inoperative?
No
Select a moisture dry
setting to see if
machine stops after
approximately six
minutes. If not,
inspect bar
sensor/wiring.
Yes
Check and replace any
inoperative seals
between the following
areas: Loading door
and front panel,
front panel and front
bulkhead, blower
cover and air duct,
and cylinder and
front or rear
bulkhead.
Yes
Continued on
next page
Troubleshooting Flowcharts
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
32
Part No. D515517ENR3
Содержание ZDE3SRGS173CW01
Страница 2: ......