Red
5
240 V 60 Hz.
10.39 ± .31
Ohms Cold
White
4.75
208 V 60 Hz.
8.2 ± .5 Ohms
Cold
Orange
5.35
240 V 60 Hz.
9.72 ± .3
Ohms Cold
Purple
4.25
208 V 60 Hz.
9.27 ± .3
Ohms Cold
Cycling or Limit Thermostat
1. While supporting the access panel, remove two screws from
bottom edge of access panel.
2. Gently lower the access panel to disengage panel locators
from bottom edge of front panel.
3. Label and disconnect wires from thermostat.
NOTE: Refer to wiring diagram when rewiring ther-
mostat.
4.
Cycling Thermostat (S.P.S.T. – 2 Terminals) or Limit
Thermostat
a. Set meter to read Ohms.
b. Apply meter probes to the thermostat terminals.
c. Meter should read “zero.”
Door Switch
1. While supporting the access panel, remove two screws from
bottom edge of access panel.
2. Gently lower the access panel to disengage locators from bot-
tom edge of front panel.
3. Remove two screws holding bottom tabs on front panel to
dryer side panels. Swing bottom of front panel away from
dryer far enough to disengage hold-down clips and locators
from cabinet top.
4. Disconnect wires from door switch.
NOTE: Refer to model wiring diagram when rewiring
door switch.
5. Set meter to read Ohms and apply meter probes on switch ter-
minals 1 and 3 with door closed. You should get “zero” read-
ing.
6. Apply probes to terminals 1 and 2 with door closed. The me-
ter should read “infinite”.
7. Open door. Meter should read “infinite” between 1 and 3 and
“zero” between 1 and 2.
Test Procedures
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
50
Part No. D515517ENR3