Error Codes - Electronic Control Models
WARNING
To reduce the risk of electric shock, fire, explosion,
serious injury or death:
• Disconnect electric power to the dryer before
servicing.
• Close gas shut-of valve to gas dryer before serv-
icing.
• Never start the Dryer with any guards/panels re-
moved.
• Whenever ground wires are removed during serv-
icing, these ground wires must be reconnected to
ensure that the dryer is properly grounded.
W001R1
Display
Description
Cause/Corrective
Action
Er
ro
Locked rotor error:
The motor is not
sensed as rotating
when it should be.
Terminate cycle and
check that nothing
is obstructing motor
rotation. Check
wire harness con-
nection between
motor, user control
and output board,
or try replacing the
user control or the
output board. If
problem persists,
replace motor.
Er
oP
Open thermistor er-
ror: The thermistor
circuit is sensed as
being physically
open.
Remove any lint
build up around
thermistor. Check
wire harness con-
nection between
thermistor and har-
ness. If problem
persists replace
thermistor, harness
or output board.
Thermistor must no
longer be seen as
open to clear.
Table continues...
Er
SH
Shorted thermistor
error: The thermis-
tor circuit is sensed
as being shorted.
Remove any lint
build up around
thermistor. Check
wire harness con-
nection between
thermistor and har-
ness. Unplug dryer
or turn circuit
breaker off/on to
clear error. If prob-
lem persists replace
thermistor, harness
or output board.
Thermistor must no
longer be seen as
shorted to clear.
Er
nS
Motor output short-
ed error: Hardware
error.
Terminate cycle.
Replace output
board. Power down
machine to clear.
Er
59
Door input acquisi-
tion error: Hard-
ware error.
Terminate cycle.
Replace output
board. Power down
machine to clear.
Er
60
Centrifugal switch
input acquisition er-
ror: Hardware error.
Terminate cycle.
Replace output
board. Power down
machine to clear.
Er
61
High limit thermo-
stat input acquisi-
tion error: Hard-
ware error.
Advance cycle to
cool down. Replace
output board. Pow-
er down machine to
clear.
Er
Co
Output board com-
munication error:
Communication
failure.
Power down ma-
chine to clear, pow-
er up and try again.
If error persists,
check harness con-
nection between
user control and
output board, or try
replacing the user
control or the out-
put board.
Er
nr
Output board not
ready error: Hard-
ware failure.
Terminate cycle.
Replace output
board. Power down
machine to clear.
Table continues...
Error Codes - Electronic Control Models
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT