39201
43
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
W003
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
(6) Remove security bolt (if present) from left
rear corner of cabinet top.
NOTE: When lowering cabinet top into position or
reinstalling cabinet top, pivot outer tub forward far
enough to prevent damaging (bending) loading door
switch lever.
i. Lift front of cabinet top slightly and pull
forward to disengage from rear hinges.
j. Pull top forward far enough to permit
disconnecting ground wires from top rear
corner gusset of washer cabinet. Refer to
Figure 39. Disconnect wires from mixing valve
solenoids at rear of washer.
NOTE: Refer to appropriate wiring diagram when
rewiring mixing valve solenoids.
k. Carefully lift cabinet top off washer and set on
protective padding.
IMPORTANT: When reinstalling cabinet top and
before lowering top into position, pivot outer tub
forward far enough to prevent damaging (bending)
door switch lever.
To reduce the risk of serious injury, be
careful not to damage door switch when
removing cabinet top.
W180
WARNING
Figure 39
W497SE3B
PRESSURE
HOSE
CORNER
GUSSET
GROUND
WIRE
MIXING
VALVE
WIRE
HARNESS
DISCONNECT
BLOCKS
DOOR
SWITCH