39201
33
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
W003
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
(5) Lift up front face plate of coin drop with
one hand, while gently pushing down rear
of drop with other hand, so the bottom of
the drop’s front face plate clears coin
drawer housing. Refer to Figure 23.
(6) Carefully slide coin drop forward into
position, as shown in Figure 24. (Front face
plate of coin drop should be secure against
front plate of meter case.)
(7) Using a 7/16 inch socket with No. 310P4
1/4 inch Ratchet Extension Tool, reinstall
the two locknuts previously removed.
Tighten locknuts firmly.
(8) Reinstall coin drawer switch previously
removed.
(9) Reconnect wires by referring to the wiring
diagram located inside the control hood.
(10) Reinstall service door switch and wire
harness into meter case bracket. Refer to
Figure 15.
(11) Reinstall multiplier and reconnect wires.
Refer to Figure 16.
(12) Close and lock service door.
Figure 23
W416SE1A
REAR OF
COIN DROP
COIN
DRAWER
HOUSING
COIN DROP
FRONT
FACE PLATE
Figure 24
W417SE1A
COIN DROP
FRONT
FACE PLATE
FRONT PLATE
OF METER CASE