88
F238006
Section 5 Service Procedures
To reduce the risk of electrical shock, fire, explosion, serious injury or death:
• Disconnect electrical power to the washer-extractor before servicing it.
• Close the gas shut-off valve to the washer-extractor (when applicable) before servicing it.
• Never start the washer-extractor with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer-extractor is properly grounded.
W461R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
40. BEARINGS AND CARTRIDGE SEAL
REPLACEMENT
a. Remove the three screws and the door lock
cover from the front of machine. Refer to
Figure 27.
b. Disconnect the spray rinse hose from the spray
tube assembly. Refer to Figure 27.
c. Remove the front, back, top and side panels.
Refer to Figure 28.
d. Using a permanent marker, make a mark on the
shell front and shell so that the shell front will
be reinstalled in the correct position.
e. Remove the nut, bolt and shell band from
around the door. Refer to Figures 29 and 30.
f. Remove the rubber trim from around the
door/shell.
g. Pull the shell front off of the machine.
Figure 27
PHM206K
¨
P
U
S
H
1
2
1
Door lock cover with 3 screws
2
Spray rinse hose
Figure 28
PHM204K
¨
P
U
S
H
Machine Panels