58
F238006
Section 4 Troubleshooting
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
13. AUTOMATIC SUPPLY DISPENSER ANALYSIS
Program and run the following steps into any available cycle to test the system.
NOTE: Pre-programmed cycle 39 already has a portion of this cycle pre-programmed into it.
Run the cycle and, with the respective supply on the main display, refer to the following chart for the function
that should be occurring:
During each step, test for voltage (220 Volts) between each respective supply terminal and the common
terminal on the XT3 terminal strip.
NOTE: The XT3 terminal strip is located toward the back of the control module, next to the power input
block.
Step
Description
Program
Min:sec
1
Warm Fill to Low Level
Warm Fill
5:00
2
Supply 1
Supply 1
2:00
3
Supply 2
Supply 2
2:00
4
Supply 3
Supply 3
2:00
5
Supply 4
Supply 4
2:00
6
Supply 6
Supply 5 and 1
2:00
7
Supply 7
Supply 5 and 2
2:00
8
Supply 8
Supply 5 and 3
2:00
9
Supply 9
Supply 5 and 4
2:00
10
Wash 1
Wash
:30
11
Drain 1
Drain
1:00
Supply
Function
1
Flushes Compartment 1
2
Flushes Compartment 2
3
Flushes Compartment 3
4
Flushes Compartments 4 and 5
6
Flushes Compartment 1
7
Flushes Compartment 2
8
Flushes Compartment 3
9
Flushes Compartments 4 and 5