Section 5 Service Procedures
To reduce the risk of electrical shock, fire, explosion, serious injury or death:
• Disconnect electrical power to the washer-extractor before servicing it.
• Close the gas shut-off valve to the washer-extractor (when applicable) before servicing it.
• Never start the washer-extractor with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer-extractor is properly grounded.
W461R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
h. Remove the belt from the pulley. Remove the
bolts from the pulley and place them in the hub
bushing. Tighten those bolts equally until the
bolts force the bushing from the hub. Remove
the pulley. Refer to Figure 31.
i. If the machine’s bearings are similar to
Figure 32 (old style bearing), loosen the lock
collar set screws until both of the collars can be
slid off of their bearing inner races. Grasp the
inner race of the bearing with a pipe wrench and
rotate the shaft by turning the basket. If this
fails to free the bearing, Alliance Laundry has a
tool to assist in loosening and removing the
bearing.
j. If the machine’s bearings are similar to
Figure 33 (new style SKF bearing), loosen
the
front and
the
rear bearing’s set screws (until 3
threads are showing) using a short 3mm Allen
wrench.
Figure 31
PHM198K
1
Belt
2
Pulley
3
Rear bearing
4
Front bearing
1
2
3
4
Figure 32
Figure 33
PHM207K
1
2
1
Bearing (Old style)
2
Lock collar set screws
PHM208K
2
1
1
SKF bearing
2
Set screws