• Skip + continue : the actual cycle step is skipped and the
program continues with the next step.
• Continue : the program continues.
SPECIAL CASES :
• For E19, 20: Defective Temperature sensor and E35: Wrong
software version The Failure message can only be erased by
switching the power off and back on.
• Fault 41: Service Due will occur over and over again until
you have reset the cycle counter. See Paragraph
Overview
how to reset the cycle counter.
RESET KEY :
• When you have overruled an error message and opened the
door, Reset Key will be displayed.
• This message warns the operator that the programming switch
is still in Program mode.
• Before you can start a new program you have to switch the
programming switch back to Run mode.
! ! Reset Key ! !
» Switch the programming switch to Run mode.
MESSAGE “CLOSE THE LINT FILTER DOOR”
• This message indicates that the lint filter door is open during
machine operation.
• Close the lint filter.
• If the message keeps showing even after the door has been
closed, check the power feed of the controller board and the
fuses.
Clean Filter
UNLOAD CLEAN FILTER
• It’s a good attitude to clean the Lint Filter each day. (See also
Installation and maintenance manual).
• As safety is involved, when the Lint Filter has not been
cleaned sooner then 15 succeeding cycles, a warning will be
displayed at the end of the drying cycle. „CLEAN FILTER“
• As the amount of lint depends on the kind of fabrics it’s possi-
ble to adjust the number of cycles, for which the warning is
generated, in the Configuration menu.
• Only by opening the lint door the Lint Filter Door Cycle
Counter will be reset.
• By opening the Dryer Door the warning on the display is
erased but the Lint Filter Door Cycle Counter is not reset.
• You can check the Lint Filter Door Cycle Counter at the Run-
ning State-Service Menu which is accessible by the special
function button on the keypad. (Press ARROW RIGHT but-
ton to go to the next menu item.) (Only valid for machines
executed with an electric contact at the Lint Door)
Overview
N°
Failure Message
Failure
Action
Fault Occurrence
E1
Heating Safety 1
Heated air too hot
Heating Off, Full Stop at
safe temperature
Whole cycle
E2
Heating Safety 2
Heater too hot
Heating Off, Full Stop at
safe temperature
Whole cycle
E3 (1)
PresSensLow
Low pressure in the heat
pump circuit
Heating Off, Full Stop at
safe temperature
Whole cycle
E4 (1)
PresSensHigh
High pressure in the heat
pump circuit
Heating Off, Full Stop at
safe temperature
Whole cycle
E5
Motor Thermic
Motor Security Trips
Heating Off, Full Stop at
safe temperature
Motor contactor on
E6
Fan Motor Thermic
Fan Motor Security Trips
Heating Off, Full Stop at
safe temperature
Motor contactor on
E7
Drum Motor Thermic
Drum Motor Security Trips Heating Off, Full Stop at
safe temperature
Motor contactor on
E8
Airflow switch Open at
Startup
Airflow switch at start-up
Heating OffFull Stop at
safe temperature
At Start-up
Table continues...
Troubleshooting
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
37
Part No. D1621ENR3
Содержание SGHP190E