Section 7 Test Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
d. Motor Windings (Refer to SECTION 8.)
G. 1
–
2 ohms between black wire
and orange wire.
Start Winding
Inoperative start winding.
Replace motor.
H. 1
–
2 ohms between yellow
wire and orange wire.
Inoperative run main
winding. Replace motor.
I.
Continuity exists between
orange wire and brown wire.
Inoperative run main
winding. Replace motor.
All motor windings check O.K.
Run Main Winding
Protector
NO
YES
NO
NO
YES
YES
Disconnect electric power to dryer before performing any of the
following steps or when replacing inoperative motor switches.
W260
WARNING