505692
41
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
42. CABINET TOP
a. While supporting the access panel, remove two
screws from bottom edge of access panel. See
Figure 5.
b. Gently lower the access panel to disengage
locators from bottom edge of front panel. See
Figure 12.
c. Remove two screws holding bottom tabs on
front panel to dryer side panels. See Figure 12.
Swing bottom of front panel away from dryer
far enough to disengage hold-down clips and
locators from cabinet top.
d. Disconnect wires from door switch. See
NOTE: Refer to wiring diagram when rewiring
switch.
e. Remove two cabinet top hold-down screws.
f. Lift cabinet top to a vertical position by hinging
it on the rear hold-down brackets. See
Figure 24.
NOTE: Cabinet top may be raised and hinged on
the rear hold-down brackets or supported against
wall behind dryer while servicing.
g. Carefully withdraw wire harness through hole
in cabinet top and lift the top off the top
brackets. See Figure 24.
Figure 24
CABINET TOP
HOLD-DOWN SCREWS
D252SE3A
REAR
HOLD-DOWN
BRACKETS
D339SE3A