Section 3 Troubleshooting
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
11. HEATER ASSEMBLY OR BURNER DOES NOT SHUT OFF
12. CLOTHES DO NOT DRY
POSSIBLE CAUSE
TO CORRECT
Improper motor switch. (Timer must be in a heat
setting.)
• Test switch and replace if inoperative.
Motor does not stop.
Incorrect wiring.
• Refer to wiring diagram.
Heater assembly shorted.
• Remove heater assembly and check for short.
POSSIBLE CAUSE
TO CORRECT
Heater assembly does not heat or burner does not
ignite.
Too much water in articles being dried.
• Remove excess water.
Laundry load too large.
• Remove part of load. Maximum load: Dryer cylinder one
half full of wet clothes.
Laundry load too small.
• Add one or two bath towels to load.
Excessive lint on lint filter.
• Clean lint filter.
Automatic cycle.
• Adjust timer knob to More Dry setting.
Heat selector switch or timer set on FLUFF or
inoperative.
• Reset switch or timer, or test and replace the switch or
timer if inoperative.
Improper or inadequate exhaust system.
• See INSTALLATION INSTRUCTIONS (supplied with
dryer) for exhaust requirements.
Heater assembly or burner shuts off prematurely.
Gas Models: Gas line pressure too high or too low.
• If Natural Gas line pressure to dryer exceeds 8 inch water
column pressure, or is lower than 4 inch water column, ask
Gas Company to correct.
Improper belt installation (low RPM).