46. CYLINDER ROLLERS
a. While supporting the access panel, remove two
screws from bottom edge of access panel. See
Figure 5.
b. Gently lower the access panel to disengage
locators from bottom edge of front panel. See
Figure 12.
c. Remove two screws holding bottom tabs on
front panel to dryer side panels. See Figure 12.
Swing bottom of front panel away from dryer
far enough to disengage hold-down clips and
locators from cabinet top.
d. Disconnect wires from door switch. See
NOTE: Refer to wiring diagram when rewiring
switch.
e. Disengage belt from motor and idler pulleys.
f. Remove four screws holding bulkhead to front
flange of cabinet. Then lift complete bulkhead
assembly out of slots in cabinet. See Figure 25.
IMPORTANT: When reassembling, be sure seal on
exhaust fan cover makes airtight seal on flange of
duct. See Figure 16. If the seal is installed
improperly, the airflow through the exhaust system
will be restricted which can adversely affect dryer
performance.
g. Pull cylinder forward allowing rear of cylinder
to drop down exposing rollers. See Figure 31.
h. See Figure 31 for removal of roller from
bulkhead.
NOTE: When replacing the cylinder roller, it is
important that cylinder roller is installed with the
flanged surface of the roller bearing facing towards
the front of the dryer.
47. OUTLET COVER
NOTE: Outlet cover is not removable from the
heater duct assembly that originally came with the
dryer. It is only removable from the replacement
heater duct assembly, Part No. 503607P.
a. Open door and remove two screws holding
outlet cover to heater duct assembly. See
Figure 30.
To reduce the risk of serious injury or death
by carbon monoxide and other gases in gas
dryers, carefully read and follow all
instructions given in this section.
W005
WARNING
Figure 31
ROLLER
BRACKET
SHAFT
SCREW
RETAINER
RING
FLANGED SURFACE
OF ROLLER BEARING
(Must face towards front of dryer)
LOCKNUT
WASHERS
REAR
BULKHEAD
D260SE1A