36
505692
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
39. THERMOSTAT AND HEATER
a. While supporting the access panel, remove two
screws from bottom edge of access panel. See
Figure 5.
b. Gently lower the access panel to disengage
locators from bottom edge of front panel. See
Figure 12.
c. Disconnect wires and remove thermostat
attaching screws, thermostat and heater, if
present. See Figure 16.
Figure 16
Figure 17
40. AIR DUCT
a. Lower Air Duct
(1.) While supporting the access panel, remove
two screws from bottom edge of access
panel. See Figure 5.
(2.) Gently lower the access panel to disengage
locators from bottom edge of front panel.
See Figure 12.
IMPORTANT: When installing lint filter, be sure to
install the filter with the words facing the front of
the dryer. If filter is installed backwards, lint will
accumulate in exhaust system, which can adversely
affect dryer performance.
(3.) Remove three screws holding lower duct to
upper duct and remove lower air duct. See
Figure 17.
IMPORTANT: When reassembling, be sure seal on
exhaust fan cover makes airtight seal on flange of
duct. See Figure 16. If the seal is installed
improperly, the airflow through the exhaust system
will be restricted which can adversely affect dryer
performance.
b. Upper Air Duct
(1.) While supporting the access panel, remove
two screws from bottom edge of access
panel. See Figure 5.
(2.) Gently lower the access panel to disengage
locators from bottom edge of front panel.
See Figure 12.
(3.) Remove three screws holding upper air
duct to lower air duct.
ATTACHING
SCREWS
SEAL
THERMISTOR
OR THERMOSTAT
WIRE
HARNESS
D324SE1A
AIR DUCT
ATTACHING SCREWS
LOWER
AIR DUCT
MOTOR
WIRE
HARNESS
D246SE3B
To reduce the risk of serious injury or death
by carbon monoxide and other gases in gas
dryers, carefully read and follow all
instructions given in this section.
W005
WARNING