Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
b. Power Cord:
(1.) Remove access plate on rear of cabinet.
(2.) Remove strain relief.
(3.) Remove screw holding power cord ground
wire to rear bulkhead. See Figure 34.
NOTE: Reinstall screw and ground wires into same
hole in bulkhead when reinstalling power cord.
(4.) Disconnect molex plug and remove power
cord from rear of dryer cabinet.
NOTE: A qualified electrician should check the
polarity of the wall receptacle. If a voltage reading
is measured other than that illustrated, the qualified
electrician should correct the problem.
Figure 34
GROUND
WIRES
GROUND
L1
NEUTRAL
SIDE
115±12
V.A.C.
115±12
V.A.C.
0
V.A.C.
D263SE3B