background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

506126

6

Place the dryer in position, and adjust the legs until the 

dryer is level from side to side and front to back. The 

dryer must not rock.

Figure 3 

IMPORTANT: In mobile home installations, gas 

dryers MUST be permanently attached to the floor 

at the time of installation. Order No. 526P3 Dryer 

Installation Kit (available at extra cost) for a 

manufactured (mobile) home installation. Follow 

the instructions supplied with the kit.

Step 2: Connect Dryer Exhaust System

DO NOT use plastic or thin foil ducting. Rigid 

metal duct is recommended.

Locate dryer so exhaust duct is as short as 

possible.

Be certain old ducts are cleaned before installing 

your new dryer.

Use 4 inch (102 mm) diameter rigid or flexible 

metal duct.

The male end of each section of duct must point 

away from the dryer.

Use as few elbows as possible.

DRY2345N

1

Dryer Base

2

Level

3

Leveling Leg

1

2

3

A clothes dryer produces combustible lint. 

To reduce the risk of fire and combustion 

gas accumulation the dryer MUST be 

exhausted to the outdoors.

W116

To reduce the risk of fire and the 

accumulation of combustion gases, DO NOT 

exhaust dryer air into a window well, gas 

vent, chimney or enclosed, unventilated 

area, such as an attic, wall, ceiling, crawl 

space under a building or concealed space 

of a building.

W045

WARNING

DRY688N

Figure 4 

This gas appliance contains or produces a 

chemical or chemicals which can cause 

death or serious illness and which are 

known to the State of California to cause 

cancer, birth defects, or other reproductive 

harm. To reduce the risk from substances in 

the fuel or from fuel combustion, make sure 

this appliance is installed, operated, and 

maintained according to the instructions in 

this manual.

W115

To reduce the risk of fire, DO NOT use 

plastic or thin foil ducting to exhaust the 

dryer.

W354

WARNING

DRY688N

DON’T

DO

Содержание 506126R5

Страница 1: ...w comlaundry com Installation Instructions for Front Control Dryers Dimensions 3 Before You Start 4 Installing the Dryer 5 Installer Checklist Back Cover Date Purchased __________________________ Mode...

Страница 2: ...er s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier W052 FOR YOUR SA...

Страница 3: ...6 cm 4 0 in 10 2 cm 26 9 in 68 3 cm ELECTRIC DRYERS 8 0 in 20 3 cm 15 4 in 39 1 cm 15 44 in 39 2 cm 37 44 in 95 1 cm DRY2282N With leveling legs turned into base 1 3 8 in NPT Gas Connection DRY2282N...

Страница 4: ...u Start Supplies For most installations the basic supplies you will need are Figure 1 D818I 1 Wrench 2 Screwdriver 3 Level 4 Duct Tape 5 Teflon Tape Gas Models 1 2 3 5 4 Any disassembly requiring the...

Страница 5: ...tion and for easier installation and servicing Minimum clearances are shown below Figure 2 DRY1914N NOTE For new installations locate top of wall vent 42 inches 106 7 cm above floor to make venting ea...

Страница 6: ...e dryer Use as few elbows as possible DRY2345N 1 Dryer Base 2 Level 3 Leveling Leg 1 2 3 A clothes dryer produces combustible lint To reduce the risk of fire and combustion gas accumulation the dryer...

Страница 7: ...secured to mobile home structure Dryer exhaust duct MUST NOT terminate under mobile home Exhaust duct must not be connected to any other duct vent or chimney Dryer exhausts 220 cfm measured at back of...

Страница 8: ...in operation outer end of exhaust pipe must have a weather hood with hinged dampers obtain locally NOTE Weather hood should be installed at least 12 inches 30 5 cm above the ground Larger clearances...

Страница 9: ...in NPT pipe plug must be installed as shown for checking inlet pressure Refer to Figure 5 To reduce the risk of gas leaks fire or explosion The dryer must be connected to the type of gas as shown on...

Страница 10: ...ram is located behind the control panel inside the control cabinet Grounding Information This appliance must be grounded In the event of malfunction or breakdown grounding will reduce the risk of elec...

Страница 11: ...Do not connect dryer to 110 115 or 120 Volt circuit Heating elements are available for field installation in dryers which are to be connected to electrical service of different voltage than that list...

Страница 12: ...30 Ampere Fuses or Circuit Breaker 6 Neutral 3 Neutral Wire 7 Terminal Block in Dryer NOTE The power cord is NOT supplied with the electric dryer Type of power cord and gauge of wire must conform to l...

Страница 13: ...n before plugging the cord into an outlet Use an acceptable indicating device connected to the center grounding pin of the plug and the green screw on the back of the cabinet 8 Reinstall access cover...

Страница 14: ...ws a Red wire to L1 terminal b Black wire to L2 terminal c White wire to Neutral terminal NOTE When installing the white wire loop the free eyelet end of the ground wire removed in Step 4 and attach a...

Страница 15: ...t then pull down removing door liner from door panel 4 Rotate door panel 180 degrees as shown 5 Remove door strike from door liner and reinstall on opposite side 6 Insert liner under flange on bottom...

Страница 16: ...operate both a washer and gas dryer on the same circuit Use separetely fused 15 amp circuits The dryer is designed to be operated on a separate branch polarized three wire effectively grounded 120 Vo...

Страница 17: ...e problem Do not operate other appliances on the same circuit when this appliance is operating Step 8 Recheck Steps 1 7 Refer to Installer Checklist on the back cover of this manual and make sure that...

Страница 18: ...to obtain a soft uniform blue flame A lazy yellow tipped flame indicates lack of air A harsh roaring very blue flame indicates too much air Adjust the air shutter as follows 1 Loosen the air shutter l...

Страница 19: ......

Страница 20: ...EVEL D255I D255I 2 DRY688N Connect Dryer Exhaust System CHECK DRY688N 3 GAS ONLY D258I CHECK Connect Gas Supply Pipe Check for Gas Leaks 4 D699IE0A ELECTRIC ONLY Connect Electrical Cord CHECK D699IE0A...

Отзывы: