Alliance Laundry Systems 506126R5 Скачать руководство пользователя страница 14

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

506126

14

3. Remove the three screws holding the three wires 

to the terminal block terminals. 

Save these 

screws. 

Loosen the strain relief screw and pull 

the cord or wires out through the rear of the 

dryer.

4. Remove ground screw and save for use in Step 6. 

Remove wire and use in Step 7.

Figure 13 

5. Use a strain relief and insert end of power cord 

through power supply hole.

Figure 14 

6. Attach power cord ground (green) wire to rear 

bulkhead using ground screw removed in Step 4.

7. Use the three screws from the accessories bag to 

attach the remaining power cord wires to the 

terminal block as follows:
a. Red wire to “L1” terminal.
b. Black wire to “L2” terminal.
c. White wire to Neutral terminal.

NOTE: When installing the white wire, loop the 

free eyelet end of the ground wire (removed in 

Step 4) and attach along with the white wire to the 

neutral (center) terminal on the terminal block.

8. Tighten all screws firmly.

IMPORTANT: Failure to tighten these screws 

firmly may result in wire failure at the terminal 

block.

9. Check the continuity of the ground connection 

before plugging the cord into an outlet. Use an 

acceptable indicating device connected to the 

center grounding pin of the plug and the green 

screw on the back of the cabinet.

10. Reinstall access cover and screw.

D696I

Figure 12 

D697I

1

Ground Screw

D698I

1

Power Cord Ground Wire

D697I

1

D698I

1

DRY522N

1

“L1” Terminal

2

White

3

“L2” Terminal

4

Black

5

Green

6

Red

7

Neutral Terminal

Figure 15 

1

7

2

3

4

5

6

Содержание 506126R5

Страница 1: ...w comlaundry com Installation Instructions for Front Control Dryers Dimensions 3 Before You Start 4 Installing the Dryer 5 Installer Checklist Back Cover Date Purchased __________________________ Mode...

Страница 2: ...er s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier W052 FOR YOUR SA...

Страница 3: ...6 cm 4 0 in 10 2 cm 26 9 in 68 3 cm ELECTRIC DRYERS 8 0 in 20 3 cm 15 4 in 39 1 cm 15 44 in 39 2 cm 37 44 in 95 1 cm DRY2282N With leveling legs turned into base 1 3 8 in NPT Gas Connection DRY2282N...

Страница 4: ...u Start Supplies For most installations the basic supplies you will need are Figure 1 D818I 1 Wrench 2 Screwdriver 3 Level 4 Duct Tape 5 Teflon Tape Gas Models 1 2 3 5 4 Any disassembly requiring the...

Страница 5: ...tion and for easier installation and servicing Minimum clearances are shown below Figure 2 DRY1914N NOTE For new installations locate top of wall vent 42 inches 106 7 cm above floor to make venting ea...

Страница 6: ...e dryer Use as few elbows as possible DRY2345N 1 Dryer Base 2 Level 3 Leveling Leg 1 2 3 A clothes dryer produces combustible lint To reduce the risk of fire and combustion gas accumulation the dryer...

Страница 7: ...secured to mobile home structure Dryer exhaust duct MUST NOT terminate under mobile home Exhaust duct must not be connected to any other duct vent or chimney Dryer exhausts 220 cfm measured at back of...

Страница 8: ...in operation outer end of exhaust pipe must have a weather hood with hinged dampers obtain locally NOTE Weather hood should be installed at least 12 inches 30 5 cm above the ground Larger clearances...

Страница 9: ...in NPT pipe plug must be installed as shown for checking inlet pressure Refer to Figure 5 To reduce the risk of gas leaks fire or explosion The dryer must be connected to the type of gas as shown on...

Страница 10: ...ram is located behind the control panel inside the control cabinet Grounding Information This appliance must be grounded In the event of malfunction or breakdown grounding will reduce the risk of elec...

Страница 11: ...Do not connect dryer to 110 115 or 120 Volt circuit Heating elements are available for field installation in dryers which are to be connected to electrical service of different voltage than that list...

Страница 12: ...30 Ampere Fuses or Circuit Breaker 6 Neutral 3 Neutral Wire 7 Terminal Block in Dryer NOTE The power cord is NOT supplied with the electric dryer Type of power cord and gauge of wire must conform to l...

Страница 13: ...n before plugging the cord into an outlet Use an acceptable indicating device connected to the center grounding pin of the plug and the green screw on the back of the cabinet 8 Reinstall access cover...

Страница 14: ...ws a Red wire to L1 terminal b Black wire to L2 terminal c White wire to Neutral terminal NOTE When installing the white wire loop the free eyelet end of the ground wire removed in Step 4 and attach a...

Страница 15: ...t then pull down removing door liner from door panel 4 Rotate door panel 180 degrees as shown 5 Remove door strike from door liner and reinstall on opposite side 6 Insert liner under flange on bottom...

Страница 16: ...operate both a washer and gas dryer on the same circuit Use separetely fused 15 amp circuits The dryer is designed to be operated on a separate branch polarized three wire effectively grounded 120 Vo...

Страница 17: ...e problem Do not operate other appliances on the same circuit when this appliance is operating Step 8 Recheck Steps 1 7 Refer to Installer Checklist on the back cover of this manual and make sure that...

Страница 18: ...to obtain a soft uniform blue flame A lazy yellow tipped flame indicates lack of air A harsh roaring very blue flame indicates too much air Adjust the air shutter as follows 1 Loosen the air shutter l...

Страница 19: ......

Страница 20: ...EVEL D255I D255I 2 DRY688N Connect Dryer Exhaust System CHECK DRY688N 3 GAS ONLY D258I CHECK Connect Gas Supply Pipe Check for Gas Leaks 4 D699IE0A ELECTRIC ONLY Connect Electrical Cord CHECK D699IE0A...

Отзывы: