506126

2

IMPORTANT: Purchaser must consult the local gas supplier for suggested instructions to be followed if the 

dryer user smells gas. The gas utility instructions plus the SAFETY and WARNING note directly above 

must be posted in a prominent location near the dryer for customer use.

The following information applies to the state of Massachusetts, USA.

This appliance can only be installed by a Massachusetts licensed plumber or gas fitter. 

This appliance must be installed with a 36 inch (91 cm) long flexible gas connector.

A “T-Handle” type gas shut-off valve must be installed in the gas supply line to this appliance.

This appliance must not be installed in a bedroom or bathroom.

• Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or 

any other appliance.

• WHAT TO DO IF YOU SMELL GAS:

– Do not try to light any appliance.

– Do not touch any electrical switch; do not use any phone in your building.

– Clear the room, building or area of all occupants.

– Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s 

instructions.

– If you cannot reach your gas supplier, call the fire department.

• Installation and service must be performed by a qualified installer, service agency or the 

gas supplier.

W052

FOR YOUR SAFETY, the information in this manual must be followed to minimize the risk of 

fire or explosion or to prevent property damage, personal injury or death.

W033

WARNING

• Installation of unit must be performed by a qualified installer.

• Install clothes dryer according to manufacturer’s instructions and local codes.

• DO NOT install a clothes dryer with flexible plastic venting materials. If flexible metal (foil 

type) duct is installed, it must be of a specific type identified by the appliance manufacturer 

as suitable for use with clothes dryers. Refer to section on connecting exhaust system. 

Flexible venting materials are known to collapse, be easily crushed, and trap lint. These 

conditions will obstruct clothes dryer airflow and increase the risk of fire.

W729R1

WARNING

FOR YOUR SAFETY

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or 

any other appliance.

W053

WARNING

© Copyright 2009, Alliance Laundry Systems LLC
All rights reserved. No part of the contents of this book may be reproduced or transmitted in any form or by any 
means without the expressed written consent of the publisher.

Содержание 506126R5

Страница 1: ...w comlaundry com Installation Instructions for Front Control Dryers Dimensions 3 Before You Start 4 Installing the Dryer 5 Installer Checklist Back Cover Date Purchased __________________________ Mode...

Страница 2: ...er s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier W052 FOR YOUR SA...

Страница 3: ...6 cm 4 0 in 10 2 cm 26 9 in 68 3 cm ELECTRIC DRYERS 8 0 in 20 3 cm 15 4 in 39 1 cm 15 44 in 39 2 cm 37 44 in 95 1 cm DRY2282N With leveling legs turned into base 1 3 8 in NPT Gas Connection DRY2282N...

Страница 4: ...u Start Supplies For most installations the basic supplies you will need are Figure 1 D818I 1 Wrench 2 Screwdriver 3 Level 4 Duct Tape 5 Teflon Tape Gas Models 1 2 3 5 4 Any disassembly requiring the...

Страница 5: ...tion and for easier installation and servicing Minimum clearances are shown below Figure 2 DRY1914N NOTE For new installations locate top of wall vent 42 inches 106 7 cm above floor to make venting ea...

Страница 6: ...e dryer Use as few elbows as possible DRY2345N 1 Dryer Base 2 Level 3 Leveling Leg 1 2 3 A clothes dryer produces combustible lint To reduce the risk of fire and combustion gas accumulation the dryer...

Страница 7: ...secured to mobile home structure Dryer exhaust duct MUST NOT terminate under mobile home Exhaust duct must not be connected to any other duct vent or chimney Dryer exhausts 220 cfm measured at back of...

Страница 8: ...in operation outer end of exhaust pipe must have a weather hood with hinged dampers obtain locally NOTE Weather hood should be installed at least 12 inches 30 5 cm above the ground Larger clearances...

Страница 9: ...in NPT pipe plug must be installed as shown for checking inlet pressure Refer to Figure 5 To reduce the risk of gas leaks fire or explosion The dryer must be connected to the type of gas as shown on...

Страница 10: ...ram is located behind the control panel inside the control cabinet Grounding Information This appliance must be grounded In the event of malfunction or breakdown grounding will reduce the risk of elec...

Страница 11: ...Do not connect dryer to 110 115 or 120 Volt circuit Heating elements are available for field installation in dryers which are to be connected to electrical service of different voltage than that list...

Страница 12: ...30 Ampere Fuses or Circuit Breaker 6 Neutral 3 Neutral Wire 7 Terminal Block in Dryer NOTE The power cord is NOT supplied with the electric dryer Type of power cord and gauge of wire must conform to l...

Страница 13: ...n before plugging the cord into an outlet Use an acceptable indicating device connected to the center grounding pin of the plug and the green screw on the back of the cabinet 8 Reinstall access cover...

Страница 14: ...ws a Red wire to L1 terminal b Black wire to L2 terminal c White wire to Neutral terminal NOTE When installing the white wire loop the free eyelet end of the ground wire removed in Step 4 and attach a...

Страница 15: ...t then pull down removing door liner from door panel 4 Rotate door panel 180 degrees as shown 5 Remove door strike from door liner and reinstall on opposite side 6 Insert liner under flange on bottom...

Страница 16: ...operate both a washer and gas dryer on the same circuit Use separetely fused 15 amp circuits The dryer is designed to be operated on a separate branch polarized three wire effectively grounded 120 Vo...

Страница 17: ...e problem Do not operate other appliances on the same circuit when this appliance is operating Step 8 Recheck Steps 1 7 Refer to Installer Checklist on the back cover of this manual and make sure that...

Страница 18: ...to obtain a soft uniform blue flame A lazy yellow tipped flame indicates lack of air A harsh roaring very blue flame indicates too much air Adjust the air shutter as follows 1 Loosen the air shutter l...

Страница 19: ......

Страница 20: ...EVEL D255I D255I 2 DRY688N Connect Dryer Exhaust System CHECK DRY688N 3 GAS ONLY D258I CHECK Connect Gas Supply Pipe Check for Gas Leaks 4 D699IE0A ELECTRIC ONLY Connect Electrical Cord CHECK D699IE0A...

Отзывы: