506126

12

Connecting Power Cord with Three-Wire 
Plug

NOTE: Four-wire cord is required for new branch-

circuit installations, mobile homes or where codes 

do not permit grounding through neutral.

Figure 6 

1. Disconnect power to dryer.
2. Remove access cover from rear of dryer.

Figure 7 

3. Use a strain relief and insert end of power cord 

through power supply hole.

Figure 8 

D816I

1

3 Wire Grounded Neutral 120/240 Volt, 60 Hertz 

4

Metallic or Non-Metallic Sheathed Cable 
(

Copper Wire Only

)

AC 1 Phase Service Entrance Switch Box
(Refer to NOTE above)

5

Power Cord (Not supplied with dryer)

2

30 Ampere Fuses or Circuit Breaker

6

Neutral

3

Neutral Wire

7

Terminal Block in Dryer

NOTE: The power cord is NOT supplied with the 
electric dryer. Type of power cord and gauge of wire 
must conform to local codes and instructions.

The method of wiring the dryer is optional and subject 
to local code requirements.

NOTE: Connect the dryer to the power supply with the 
MAXIMUM RATED VOLTAGE listed on the nameplate.

1

3

5

6

7

4

2

POWER CORD CONNECTION

DIRECT CONNECTION

L1

L2

L1

L2

INTERMEDIATE 
SHUT-OFF BOX 

(may or may not 

be fused)

POWER SUPPLY

POWER SUPPLY

INTERMEDIATE 

FUSE BOX (may 

be omitted if 

service entrance 

box is fused)

WALL 

RECEPTACLE

A typical 

30-Amp 

Three-Wire 
Receptacle 

NEMA Type 

10-30R

120 ± 12

V.A.C.

120 ± 12

V.A.C.

240 ± 12

V.A.C.

NOTE: Use COPPER WIRE only. 
Shorter than 15 ft. (4.5 m) – use 10 AWG
Longer than 15 ft. (4.5 m) – use 8 AWG

D695I

D696I

Содержание 506126R5

Страница 1: ...w comlaundry com Installation Instructions for Front Control Dryers Dimensions 3 Before You Start 4 Installing the Dryer 5 Installer Checklist Back Cover Date Purchased __________________________ Mode...

Страница 2: ...er s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier W052 FOR YOUR SA...

Страница 3: ...6 cm 4 0 in 10 2 cm 26 9 in 68 3 cm ELECTRIC DRYERS 8 0 in 20 3 cm 15 4 in 39 1 cm 15 44 in 39 2 cm 37 44 in 95 1 cm DRY2282N With leveling legs turned into base 1 3 8 in NPT Gas Connection DRY2282N...

Страница 4: ...u Start Supplies For most installations the basic supplies you will need are Figure 1 D818I 1 Wrench 2 Screwdriver 3 Level 4 Duct Tape 5 Teflon Tape Gas Models 1 2 3 5 4 Any disassembly requiring the...

Страница 5: ...tion and for easier installation and servicing Minimum clearances are shown below Figure 2 DRY1914N NOTE For new installations locate top of wall vent 42 inches 106 7 cm above floor to make venting ea...

Страница 6: ...e dryer Use as few elbows as possible DRY2345N 1 Dryer Base 2 Level 3 Leveling Leg 1 2 3 A clothes dryer produces combustible lint To reduce the risk of fire and combustion gas accumulation the dryer...

Страница 7: ...secured to mobile home structure Dryer exhaust duct MUST NOT terminate under mobile home Exhaust duct must not be connected to any other duct vent or chimney Dryer exhausts 220 cfm measured at back of...

Страница 8: ...in operation outer end of exhaust pipe must have a weather hood with hinged dampers obtain locally NOTE Weather hood should be installed at least 12 inches 30 5 cm above the ground Larger clearances...

Страница 9: ...in NPT pipe plug must be installed as shown for checking inlet pressure Refer to Figure 5 To reduce the risk of gas leaks fire or explosion The dryer must be connected to the type of gas as shown on...

Страница 10: ...ram is located behind the control panel inside the control cabinet Grounding Information This appliance must be grounded In the event of malfunction or breakdown grounding will reduce the risk of elec...

Страница 11: ...Do not connect dryer to 110 115 or 120 Volt circuit Heating elements are available for field installation in dryers which are to be connected to electrical service of different voltage than that list...

Страница 12: ...30 Ampere Fuses or Circuit Breaker 6 Neutral 3 Neutral Wire 7 Terminal Block in Dryer NOTE The power cord is NOT supplied with the electric dryer Type of power cord and gauge of wire must conform to l...

Страница 13: ...n before plugging the cord into an outlet Use an acceptable indicating device connected to the center grounding pin of the plug and the green screw on the back of the cabinet 8 Reinstall access cover...

Страница 14: ...ws a Red wire to L1 terminal b Black wire to L2 terminal c White wire to Neutral terminal NOTE When installing the white wire loop the free eyelet end of the ground wire removed in Step 4 and attach a...

Страница 15: ...t then pull down removing door liner from door panel 4 Rotate door panel 180 degrees as shown 5 Remove door strike from door liner and reinstall on opposite side 6 Insert liner under flange on bottom...

Страница 16: ...operate both a washer and gas dryer on the same circuit Use separetely fused 15 amp circuits The dryer is designed to be operated on a separate branch polarized three wire effectively grounded 120 Vo...

Страница 17: ...e problem Do not operate other appliances on the same circuit when this appliance is operating Step 8 Recheck Steps 1 7 Refer to Installer Checklist on the back cover of this manual and make sure that...

Страница 18: ...to obtain a soft uniform blue flame A lazy yellow tipped flame indicates lack of air A harsh roaring very blue flame indicates too much air Adjust the air shutter as follows 1 Loosen the air shutter l...

Страница 19: ......

Страница 20: ...EVEL D255I D255I 2 DRY688N Connect Dryer Exhaust System CHECK DRY688N 3 GAS ONLY D258I CHECK Connect Gas Supply Pipe Check for Gas Leaks 4 D699IE0A ELECTRIC ONLY Connect Electrical Cord CHECK D699IE0A...

Отзывы: