Rockwell Automation Publication 750-UM006C-EN-P - March 2022
121
Configure and Start Up the Drive
Chapter 4
4. Click OK to exit Module Properties.
Configure Digital Outputs
Use the Digital Outputs page to enter digital output values for the drive option
module. The Digital Outputs page applies only to a PowerFlex 755 drive that is
configured with a Digital I/O option module as a peripheral device. The
appearance of the Digital Outputs page varies dependent upon the option
module configuration.
Use the Digital Output page to assign specific actions to the outputs on the
I/O option module that is located in slot 7 of the drive.
See the electric drawings to observe that Digital Output 1 is wired in parallel to
Digital Output 2. From the 20-750-2263C-1R2T option module, relay 0 and
transistor 0 are wired in parallel.
The Logix controller can have logic written that may energize Output 2 when
the axis isn't running. This logic releases the motor brake, but only on
horizontal applications.
1. On the Module Properties dialog box, choose Digital Output.
Digital Output
Description
1
20-750-2263C-1R2T Relay 0
2
20-750-2263C-1R2T Transistor Relay Output 0
3
20-750-2263C-1R2T Transistor Relay Output 1 (not used)
ATTENTION:
Failure to observe this warning can result in machine damage
or personnel injury. Do not use Output 2 shown in
on page
, when
the application is vertical (Gravity can influence movement).
Содержание The PowerFlex 755 On-Machine
Страница 1: ...User Manual Original Instructions PowerFlex 755 On Machine Drive Bulletin Number 26G...
Страница 208: ...208 Rockwell Automation Publication 750 UM006C EN P March 2022 Appendix B Startup Information Notes...
Страница 216: ...216 Rockwell Automation Publication 750 UM006C EN P March 2022 Index Notes...
Страница 217: ...Rockwell Automation Publication 750 UM006C EN P March 2022 217 PowerFlex 755 On Machine Drive User Manual...