Rockwell Automation Publication 750-UM006C-EN-P - March 2022
Chapter 4
Configure and Start Up the Drive
Choose Startup Mode
Two options are available for integrating the PowerFlex 755 drive with Logix
controllers. The bullets below help you determine when to use which mode:
Drive I/O Mode
Drive I/O mode uses Drive Add-on Profiles (AOPs) with Studio 5000
environment. Version 30.00 and later of Studio 5000 Logix designer is used for
Network Integrated Safety Function (S4) and version 20.00 and later is used
for Safe Torque Off (S3).
• The I/O mode on EtherNet/IP application is a Studio 5000
environment feature. It provides a similar user experience as the
Rockwell Automation AC drives that are used with Logix controllers
on an EtherNet/IP network, such as: PowerFlex 523, 525, 70, 700,
and 753.
• Applications such as fans, pumps, conveyors, and simple position
applications such as turntables, framers, trunnions, and vertical lifts.
• I/O mode does not use motion instructions, but uses AOPs to create
and store drive parameters and Logix tags to control the drive.
IMPORTANT
Before you can configure your drive in the Logix Designer application, you
must have a controller project with an EtherNet/IP network connection
configured and Time Sync enabled. See the documentation for your
controller for information on configuring those products. For safety
applications, you need a GuardLogix or Compact GuardLogix safety
controller.
Содержание The PowerFlex 755 On-Machine
Страница 1: ...User Manual Original Instructions PowerFlex 755 On Machine Drive Bulletin Number 26G...
Страница 208: ...208 Rockwell Automation Publication 750 UM006C EN P March 2022 Appendix B Startup Information Notes...
Страница 216: ...216 Rockwell Automation Publication 750 UM006C EN P March 2022 Index Notes...
Страница 217: ...Rockwell Automation Publication 750 UM006C EN P March 2022 217 PowerFlex 755 On Machine Drive User Manual...