Battery Replacement
The PanelView 800 terminals contain a lithium battery that is intended to be
replaced during the life of the product. The battery provides battery backup for
the real-time clock. It is not used for application backup or retention.
WARNING:
Verify that power has been removed from the terminal
prior to replacing the battery. Work in a static free environment and
wear a properly grounded electrostatic discharge (ESD) wristband.
Be careful when touching any of the exposed electronic components to
prevent damage from ESD.
WARNING:
To avoid the danger of explosion, only replace the battery
with 2711P-RY2032 or a manufacturer’s equivalent such as the
Matsushita or Duracell DL2032.
For safety information on the handling of lithium batteries, see the
Guidelines for Handling Lithium Batteries, publication
Do not dispose of battery in a fire or incinerator. Dispose of used
batteries in accordance with local regulations.
WARNING:
When you connect or disconnect the battery an electrical
arc can occur. This could cause an explosion in hazardous location
installations. Be sure that the area is nonhazardous before proceeding.
For Safety information on the handling of lithium batteries, including
handling and disposal of leaking batteries, see Guidelines for Handling
Lithium Batteries, publication
Do not dispose of battery in a fire or incinerator. Dispose of used
batteries in accordance with local regulations.
This product contains a lithium battery that may need to be
replaced during the life of the product. At the end of its life, the
battery contained in this product should be collected separately
from any unsorted municipal waste. The collection and recycling of
batteries helps protect the environment and contributes to the
conservation of natural resources as valuable materials are
received.
ATTENTION:
Battery contains Perchlorate Material – Special handling
may apply.
See
www.dtsc.ca.gov/hazardouswaste/perchlorate
.
This perchlorate warning only applies to primary Lithium Manganese
Dioxide (LiMnO2) cells or batteries, and products containing these cells
or batteries, sold or distributed in California, USA.
Содержание PanelView 800 2711R-T10T
Страница 1: ...User Manual PanelView 800 HMI Terminals Catalog Numbers 2711R T4T 2711R T7T 2711R T10T...
Страница 4: ...4 Rockwell Automation Publication 2711R UM001E EN E January 2017 Summary of Changes Notes...
Страница 8: ...8 Rockwell Automation Publication 2711R UM001E EN E January 2017 Table of Contents Notes...
Страница 88: ...88 Rockwell Automation Publication 2711R UM001E EN E January 2017 Chapter 5 Upgrade Firmware Notes...
Страница 98: ...98 Rockwell Automation Publication 2711R UM001E EN E January 2017 Chapter 7 Recipes Notes...
Страница 118: ...118 Rockwell Automation Publication 2711R UM001E EN E January 2017 Appendix A Specifications Notes...
Страница 142: ...142 Rockwell Automation Publication 2711R UM001E EN E January 2017 Appendix D Configure Security Notes...
Страница 156: ...156 Rockwell Automation Publication 2711R UM001E EN E January 2017 Index Notes...
Страница 157: ......