Rockwell Automation Publication 2094-IN005H-EN-P - October 2012
44
Line Interface Module
In the example configuration below, the servo drive has input power, brake
power, and the start/stop string wired from a 2094-AL09 or 2094-BL02 line
interface module. These modules contain an AC line filter, so an external filter is
not required.
Figure 38 - Power-interconnect Diagram (line interface module with drive)
L3
L2
L1
24-26
13
20-22
4
L3
L2
L1
L2
L1
L3'
L2'
L1'
IO_PWR
COIL_A1
IO_COM
COIL_A2
1
2
1
2
3
4
MBRK_PWR
MBRK_COM
MBRK_PWR
MBRK_COM
Control Power
Connections
* INDICATES USER SUPPLIED COMPONENT
Contactor Enable
Connections
Brake and I/O Output
(PSL) Connector
Drive Module *
Bonded Cabinet
Ground Bus*
VAC LINE 3-phase (IPL) Input
195-264V AC RMS
or 324-528V AC RMS
Ground Stud
Ground
VAC LOAD 3-phase (OPL) Output
195-264V AC RMS
or 324-528V AC RMS
STOP *
I/O (IOL)
Connector
2094-AL09 or 2094-BL02
Line Interface Module
Ground and
3-phase
Input (IPD)
Connections
Single-phase (CPL) Output
195-264V AC RMS
24V for motor brakes
or other as needed
24V for motor brakes
or other as needed