Wiring Guidelines
Use these guidelines as a reference when wiring the connectors on your line
interface module.
See
Wiring Diagrams
beginning on
page 43
for interconnect diagrams including
the line interface module.
Follow these steps when wiring the connectors on your line interface module.
1.
Prepare the wires for attachment to each connector plug by removing
insulation equal to the recommended strip length.
2.
Route the cable/wires to your line interface module.
3.
Insert wires into connector plugs.
See connector pinout tables beginning on
page 11
.
4.
Tighten the connector screws.
5.
Gently pull on each wire to make sure it does not come out of its terminal.
If any wires are loose, then repeat steps 3 and 4.
6.
Insert the connector plug into the appropriate connector.
IMPORTANT
See
Connector Data
on
page 9
for the connector locations of your line interface
module.
When tightening screws to secure the wires, see the tables beginning on
page 31
for
torque values.
When removing insulation from wires, see the tables beginning on
page 31
for strip
lengths.
IMPORTANT
To ensure system performance, run wires and cables in wireways as shown in
Establishing Noise Zones
on
page 6
.
IMPORTANT
Use caution not to nick, cut, or otherwise damage strands as you remove the
insulation.