Select Command and Status Bits
To Sequence Machine Operation
Chapter 6
6-3
Table 6.C
Status and Command Bit Interaction for Automatic Functions
For this
Profile/Movement
During execution
this bit in B34 is
At completion
this bit in B34 is
At completion, if this
command bit is This status bit is
SET
RESET
SET
RESET
also SET
also SET
Injection
SYS21B04 SYS02B04 SYS02B04 SYS21B04 ---
---
Pack
SYS21B05 SYS02B05 SYS02B05 SYS21B05 ---
---
Hold
SYS21B06 SYS02B06 SYS02B06 SYS21B06 HPC03B08
SYS22B06
Predecompression
SYS21B07 SYS02B07 SYS02B07 SYS21B07 HPC03B09
SYS22B07
Plastication
SYS21B08 SYS02B08 SYS02B08 SYS21B08 PPC03B08
SYS22B08
Postdecompression SYS21B09 SYS02B09 SYS02B09 SYS21B09 ---
SYS22B09
Table 6.D
Command Bits To Interrupt Ram (screw) Movement Between Profiles
Bit Description
QDC Block Address
0 = start predecompression movement @ end of hold profile
1 = stop and set output @ end of hold profile
HPC03B08
0 = start plastication profile @ end of predecompression movement
1 = stop and set output @ end of predecompression movement
HPC03B09
0 = start postdecompression movement @ end of plastication profile
1 = stop and set output @ end of plastication profile
PPC03B08
Table 6.E
Miscellaneous Status Bits To Trigger New Events in Inject Mode
Reason for Using
Bit Description
QDC Block Address
To drop pump adders, or shift solenoids before
starting pack/hold profile
Injection complete
SYS02B04
To inhibit clamp from opening in auto mode
Cure timer timing
SYS03B03
To start clampopen phase
Ram (screw) retracted, and
Cure time complete
SYS03B04, and
SYS03B05
To idle the machine and activate an alarm
because the hopper is running out of plastic
Watchdog for plastication phase
SYS04B08
To shift solenoids for predecompression
Setoutput in progress @ end of hold
SYS22B06
To shift solenoids for plastication
Setoutput in progress @ end of predecompression SYS22B07
To shift solenoids for postdecompression
Setoutput in progress @ end of plastication
SYS22B08
To idle the machine until starting next action
Setoutput in progress @ end of
postdecompression
SYS22B09