Enter Your Initial Values Here
Configure the QDC Module's I/O
Chapter 3
3-5
Category:
If your:
Then Use a Value Equal to:
Analog Signal @ Min Pressure
sensors are forwardacting
low end of your selected range
(Lines 7 and 15)
sensors are reverseacting
high end of your selected range
Analog Signal @ Max Pressure
sensors are forwardacting
high end of your selected range
(Lines 8 and 16)
sensors are reverseacting
low end of your selected range
Minimum Screw RPM (Line 9)
N/A
zero
Maximum Screw RPM
(Line 10)
N/A
max range value specified by
the manufacturer
Analog Signal @ Min RPM
sensors are forwardacting
low end of of your selected range
(Line 11)
sensors are reverseacting
high end of your selected range
Analog Signal @ Max RPM
sensors are forwardacting
high end of your selected range
(Line 12)
sensors are reverseacting
low end of your selected range
Worksheet 3D
Determine Initial Sensorconfiguration Values
Input
Line Control
Word
ProSet 600
Address
Value
Description
Units
1
1
MCC09
N40:5
0
Minimum Screw Position
Screw Axis Measured from zero
1
2
MCC10
N40:6
Maximum Screw Position
Screw Axis Measured from zero
1
3
MCC11
N40:7
Analog Signal @ Min Screw Position
Input Signal Range
2
4
MCC12
N40:8
Analog Signal @ Max Screw Position
Input Signal Range
2
2
5
MCC17
N40:13
0
Minimum Screw Pressure
Screw Pressure
3
6
MCC18
N40:14
Maximum Screw Pressure
Screw Pressure
3
7
MCC19
N40:15
Analog Signal @ Min Screw Pressure
Input Signal Range
2
8
MCC20
N40:16
Analog Signal @ Max Screw Pressure
Input Signal Range
2
3
9
MCC51
N40:47
0
Minimum Screw RPM
Rotational Speed
4
10 MCC52
N40:48
Maximum Screw RPM
Rotational Speed
4
11
MCC53
N40:49
Analog Signal @ Min Screw RPM
Input Signal Range
2
12 MCC54
N40.50
Analog Signal @ Max Screw RPM
Input Signal Range
2
4
13 MCC57
N40:53
0
Minimum Cavity Pressure
Cavity Pressure
5
14 MCC58
N40:54
Maximum Cavity Pressure
Cavity Pressure
5
15 MCC59
N40:55
Analog Signal @ Min Cavity Pressure
Input Signal Range
2
16 MCC60
N40:56
Analog Signal @ Max Cavity Pressure
Input Signal Range
2
1
Incremental Distance
2
Input Signal Range
3
Pressure
00.00 to 99.99in
00.00 to 10.00VDC or
0000 to 9999 PSI
000.0 to 999.9mm
01.00 to 05.00VDC or
000.0 to 999.9 Bar
04.00 to 20.00MADC
4
Rotational Speed
5
Pressure
000.0 to 999.9 RPM
00000 to 20,000 PSI
0000.0 to 2000.0 Bar