System Operation:
Inject Mode 0 0
Select Units
0 = English
1 = metric
Code:
Your value
Required initial value
loaded by ProSet 600
0 or 1
Configure the QDC Module's I/O
Chapter 3
3-2
Worksheet 3A
Select Module Parameters
Control Word MCC02Bxx
15
14 13 12
11
10
09 08 07 06 05 04 03 02 01 00
ProSet 600 Addr. B34/bit
543 542 541 540 539 538 537 536 535 534 533 532 531 530 529 528
Value
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
Example: If you select Inject operation with English units:
MCC02 = 00000000 00001000
Select I/O Ranges for your Sensors
Next, configure the QDC module’s I/O ranges to match the machine
sensors and valves. Refer to Worksheet 2-A from chapter 2 which you
filled out when setting the QDC module’s jumpers. Apply this information
to Worksheet 3-B for input ranges and Worksheet 3-C for output ranges.