Select Command and Status Bits
To Sequence Machine Operation
Chapter 6
6-2
Use the following tables to select command and status bits when writing
ladder logic to control manual functions and machine sequencing.
Table 6.A
Command and Status Bits for Manual Control
To Initiate this action
Set this bit
The QDC sets this bit
during execution
Direct Setoutput
DYC01B08
SYS01B08
Screw Rotate Jog
DYC01B09
SYS01B09
Ram (screw) Forward Jog
DYC01B10
SYS01B10
Ram (screw) Reverse Jog
DYC01B11
SYS01B11
Unassigned # 4 Jog
DYC01B12
SYS01B12
Unassigned # 5 Jog
DYC01B13
SYS01B13
Unassigned # 6 Jog
DYC01B14
SYS01B14
Unassigned # 7 Jog
DYC01B15
SYS01B15
Stop
DYC02B15
SYS02B15
Table 6.B
Command Bits for Automatic Functions
To initiate this
profile/movement
Toggle this bit Or the profile/movement
starts automatically after
If this bit
is Reset
Injection
DYC02B04
-
-
Pack
DYC02B05
Injection
Note 1
Hold
DYC02B06
Pack
Note 1
Predecompression
DYC02B07
Hold
HPC03B08
Plastication
DYC02B08
Predecompression
HPC03B09
Postdecompression
DYC02B09
Plastication
PPC03B08
Note 1 Injection, Pack, and Hold are always linked as one profile.
Use Command and Status