Malfunctions with Indications
2-9
SP-38
Handshake PB
(Hard)
Internal communication between the
System Processor and the Port B Adapter
Board has Malfunctioned. A controlled
motor stop will be initiated.
Execute System RESET or cycle power
and attempt normal operation. Check the
ribbon connector that plugs into J6 on the
Main Control Board and the Adapter
Board, replace if damage is suspected. If
the malfunction reoccurs, replace the
Adapter Board. If the malfunction still
reoccurs check integrity of TE and PE
grounding before replacing the Main
Control Board.
SP-39
Handshake PA
(Hard)
Internal communication between the
System Processor and the Port A Adapter
Board has malfunctioned. A controlled
motor stop will be initiated.
Execute System RESET or cycle power
and attempt normal operation. Check the
ribbon connector that plugs into J7 on the
Main Control Board and the Adapter
Board, replace if suspect. If the fault
reoccurs, replace the Adapter Board. If
the fault still reoccurs, check integrity of
TE and PE grounding before replacing
the Main Control Board.
SP-43
Port Configd-No
Adapter (Soft)
The System Processor has detected that
an Adapter Board, which has configuration
parameters linked to it, is not installed.
This could result in undesirable operation.
This fault may also occur when trying to
link configuration parameters to
non-existing adapters.
The missing Adapter Board should be
replaced or the configuration parameters
linked to the missing adapter should be
removed. A System RESET can then be
executed and operation continued.
SP-50
Mode VP/CP
Timeout (Hard)
Internal communication between
processors has malfunctioned. A
controlled motor stop will be initiated.
Execute System RESET or cycle power
and attempt normal operation. If the fault
reoccurs, replace Main Control Board.
SP-51
Mode PB Timeout
(Hard)
Internal communication between the
System Processor and the Port B Adapter
has malfunctioned. A controlled motor stop
will be initiated.
Execute System RESET or cycle power
and attempt normal operation. If the fault
reoccurs, replace the Port B Adapter. If
the fault reoccurs, replace the Main
Control Board.
SP-52
Mode PA Timeout
(Hard)
Internal communication between the
System Processor and the Port A Adapter
has malfunctioned. A controlled motor stop
will be initiated.
Execute System RESET or cycle power
and attempt normal operation. If the fault
reoccurs, replace the Port A Adapter. If
the fault persists, replace the Main
Control Board.
SP-53
Processor VP
Faulted (Hard)
The Velocity Processor has been detected
as being in a faulted state. A controlled
motor stop will be initiated.
Check the Fault Queue to see if the
Velocity Processor fault may have been
recorded. These faults must be corrected
before further operation. Execute System
RESET or cycle power and attempt
normal operation. If the fault reoccurs,
replace the Main Control Board.
System Processor Faults
No.
Name
Description
Recovery
!
ATTENTION:
Do Not execute a Clear Fault without correcting the cause of the
fault. This will allow the drive to operate and may cause undesirable operation. The
hazard of personal injury or equipment damage exists if faults are not corrected.
Aotewell Ltd industry-mall.net
www.aotewell.com
www.aotewell.com
Содержание 1395
Страница 104: ...A 14 Parameter List Record Notes Aotewell Ltd industry mall net www aotewell com sales aotewell com www aotewell com ...
Страница 106: ...Index 2 Notes Aotewell Ltd industry mall net www aotewell com sales aotewell com www aotewell com ...
Страница 107: ...Aotewell Ltd industry mall net www aotewell com sales aotewell com www aotewell com ...