Wiring System, Axis, and Shunt Modules, and Motors (for all systems)
Connecting Thermal and Brake Leads to Axis Modules
Axis modules provide terminating points for the motor power,
thermal sensor, and brake. Axis module wiring is identical for all
available axis module ratings.
Figure 3.13
Locating TB1 and TB2
Important:
Noise filters on the motor thermal sensor and brake
connectors (TB1 and TB2) add capacitance (1.0
µF)
from each leg of the thermal switch and motor
brake leads to ground. This should be considered
when selecting
ground fault circuits.
Connect the motor thermal sensor and brake lead to the Axis Module
at TB1 and TB2. Each axis module comes with a brake and thermal
connector kit. Refer to
Appendix D
for more information.
Required Tools and Equipment
•
A small, flathead screwdriver
•
One 1326-CP
x
1-
xxx
motor power cable for each axis
•
One axis module connector kit (catalog number 1394-199) for
thermal switch and brake inputs. You will need one kit per axis
module as each kit contains two connectors.
TB
1
TB
2
1
4
1
4
U1
V1
W1
PE1
PE2
PE3
Terminal:
Description:
TB1-1, 2
Thermal Sensor Input from Motor Cable
TB1-3, 4
Brake 24V DC from Motor Cable
TB2-1, 2
Brake 24V DC from Fault System
TB2-3, 4
Thermal Sensor Output to Fault System
Содержание 1394 SERCOS
Страница 1: ...User Manual 1394 Digital AC Multi Axis Motion Control System Catalog No 1394 50 Allen Bradley...
Страница 10: ...Publication 1394 5 0 May 2000 viii Table of Contents...
Страница 118: ...Publication 1394 5 0 May 2000 5 8 Wiring Your 1394 Analog Servo System...
Страница 124: ...Publication 1394 5 0 May 2000 6 6 Commissioning 1394 GMC and GMC Turbo Systems...
Страница 166: ...Publication 1394 5 0 May 2000 8 30 Configuring Your 1394 Analog Servo System...
Страница 232: ...Publication 1394 5 0 May 2000 A 34 Specifications...
Страница 292: ...Publication 1394 5 0 May 2000 D 14 Catalog Numbers...
Страница 300: ...I 8 Index Publication 1394 5 0 May 2000...