Publication 1394-5.0 — May 2000
Overview
1-3
1394 System Overview
GMC System
The 1394 GMC System provides all the functionality of the IMC S
Class Compact Motion Controller and power conversion within the
1394 system module. Allen-Bradley offers two versions of the 1394
GMC system module (Standard GMC and GMC Turbo). Both
systems are completely programmed and commissioned using
GML
(Graphical Motion Control Language), offer Allen-Bradley
DH485, RS-232, and RS-422 as standard communications, and have
Remote I/O and AxisLink available as communication options.
The 1394
x
-SJT
xx
-C (Standard GMC) system supports four axis
modules and provides four channels of auxiliary encoder input. The
1394C-SJT
xx
-L (Standard GMC) provides the same functionality of
the 1394
x
-SJT
xx
-C, but supports only one axis module and provides
two channels of auxiliary encoder input.
In addition, the 1394
x
-SJT
xx
-T (GMC Turbo) provides more GML
application program memory and executes the programs faster. The
1394
x
-SJT
xx
-T offers 64K of memory with a 32-bit processor while
the 1394
x
-SJT
xx
-C offers 32K of program memory with a 16-bit
processor. The 1394
x
-SJT
xx
-T also includes a direct, high speed link
to the SLC 5/03
, 5/04
,
or 5/05
that simplifies the programming
required to transfer data between the 1394
x
-SJT
xx
-T and the SLC
.
Figure 1.1
Two GMC Turbo Systems (1394
x
-SJT
xx
-T)
RIO
DH-485
AxisLink
GML
1326AB and 1326AS Motors
1326AB and 1326AS Motors
Flex I/O
ALEC
845H
Encoder
RS-232/-422
SLC 500
SLC 5/03, 5/04, or 5/05
1
1394
x-SJTxx-T
1394
x-SJTxx-T
PanelView 550
This interface is only available with the 1394
x-SJTxx-T system module.
1
TM
1746-C7 or -C9
1
Flex I/O
Discrete Outputs
Discrete Inputs
Analog Outputs
Analog Inputs
AEC
AEC
Reset
Axis 0
Axis 1
A
B
A
B
Ax
is
1
Ax
is
0
2
1
SSI
Control
Configur
ation
Configur
ation
Switches
Switches
Encoder
Encoder
Po
w
e
r
SSI
Control
A
B
10
9
8
7
6
2
5
4
3
1
8
7
6
2
4
3
1
5
A
B
10
9
8
7
6
2
5
4
3
1
8
7
6
2
4
3
1
5
4100-AEC
842A
Encoder
AxisLink
DANGER
RISK OF ELECTRICAL SHOCK. HIGH VOLTAGE MAY
EXIST UP TO FIVE MINUTES AFTER REMOVING POWER.
DANGER
RISK OF ELECTRICAL SHOCK. HIGH VOLTAGE MAY
EXIST UP TO FIVE MINUTES AFTER REMOVING POWER.
Содержание 1394 SERCOS
Страница 1: ...User Manual 1394 Digital AC Multi Axis Motion Control System Catalog No 1394 50 Allen Bradley...
Страница 10: ...Publication 1394 5 0 May 2000 viii Table of Contents...
Страница 118: ...Publication 1394 5 0 May 2000 5 8 Wiring Your 1394 Analog Servo System...
Страница 124: ...Publication 1394 5 0 May 2000 6 6 Commissioning 1394 GMC and GMC Turbo Systems...
Страница 166: ...Publication 1394 5 0 May 2000 8 30 Configuring Your 1394 Analog Servo System...
Страница 232: ...Publication 1394 5 0 May 2000 A 34 Specifications...
Страница 292: ...Publication 1394 5 0 May 2000 D 14 Catalog Numbers...
Страница 300: ...I 8 Index Publication 1394 5 0 May 2000...