Publication 1394-5.0 — May 2000
Configuring Your 1394 Analog Servo System
8-15
[Mod Rng Data]
Diagnostic information of data communicated
between the controller and Axis Module.
Parameter Numbers
196, 197, 198, 199
Parameter Group
Linear List
Parameter Type
Read Only
[Mode Sel]
This parameter modifies both [Vel Source] and
[Torq Source] to appropriate value based on
selection (for convenience during
commissioning).
Parameter Numbers
112, 113, 114, 115
Parameter Group
Configuration, Startup Parms
Display Units
None
Parameter Type
Read/Write
Change While Running
Yes
Linkable
No
Default Value
0
"Anlg Vel"
Selections
0
"Anlg Vel"
1
"Ana Torq"
2
"Dig Vel"
3
"Dig Torq"
[Module Size]
Current rating of the Axis Module. This is set after
the initialization of the 1394 Analog Servo
System DSP.
Parameter Numbers
324, 325, 326, 327
Parameter Group
Torq Data
Display Units
amps
Parameter Type
Read Only
Linkable
No
Bit 15
Bit 14
Bit 13
Bit 12 Bit 11
Bit 10
Bit 9
Bit 8
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Control
Read/Write
Axis Enabled
Version of axis
module EPLD
Scaling Bit
Size Bit
Ovr Temp Flt
Bus Loss Warning
I(t) Fault
Power Fault
Size Bit
Size Bit
Size Bit
Scaling Bit
Scaling Bit
Scaling Bit
Содержание 1394 SERCOS
Страница 1: ...User Manual 1394 Digital AC Multi Axis Motion Control System Catalog No 1394 50 Allen Bradley...
Страница 10: ...Publication 1394 5 0 May 2000 viii Table of Contents...
Страница 118: ...Publication 1394 5 0 May 2000 5 8 Wiring Your 1394 Analog Servo System...
Страница 124: ...Publication 1394 5 0 May 2000 6 6 Commissioning 1394 GMC and GMC Turbo Systems...
Страница 166: ...Publication 1394 5 0 May 2000 8 30 Configuring Your 1394 Analog Servo System...
Страница 232: ...Publication 1394 5 0 May 2000 A 34 Specifications...
Страница 292: ...Publication 1394 5 0 May 2000 D 14 Catalog Numbers...
Страница 300: ...I 8 Index Publication 1394 5 0 May 2000...